WARNING
Do not touch the hot zone of the welder!
Keep device away from water and meltable substances.
Open the screw clamps [9] by unscrewing the knobs
[10] and remove the joined belt.
Open the spring clamp [3] and lock the closing hook
[2].
If the welder W-01 is not in use, disconnect it from
the mains power supply.
Remove the bead with a sharp knife or by deburring
with abrasive cloth
7 Maintenance
Always keep the spring clamp clean. Clean regularly the heating plate of the welder and remove all material
residues. Clean the heating plate while heated with a cotton cloth.
Check the spring clamp [3] works correctly. If necessary, clean and slightly lubricate the pivot axis and the
alignment pin [11].
7.1 Accessory/spare parts orders
Spare parts and accessories can be directly ordered from the manufacturer at the following address:
Please clearly specify ordered part codes.
Enter codes based on Drawings (see chap
ter “SPARE PARTS”) and, if possible, the power voltage required
for mains connection.
The use of other branded spare parts that do not meet Habasit specifications is prohibited.
Habasit is not liable for the use of non-original Habasit spare parts.
Habasit Italiana S.p.A.
Via del Lavoro, 50.
31016 CORDIGNANO (TV) - ITALY
Tel.: +39 0438 9113
Fax: + 39 0438 912374
E_mail :
Internet :
www.habasit.com