Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Fax. ++39(0)438.200545
Hot Press PM-306/160
Author:
A.T. / KM
OPERATION
Edition: 09/2005
Page
D-10
Replaces:
D.5
Press operation
D.5.1
Working stationary and mobile
Stationary operation
Where the hot-pressing device is permanently positioned with available supplies of electricity,
compressed air and water. For its operation the hot-pressing device is managed by the following:
A regulating unit PMR-XX, which controls the temperature rising and a cooling unit PMC-XX.
The cooling unit PMC-XX guides the water circulation in the cooling system and subsequently empties
the circuit as well as inflating and deflating the pressure cushion (upper and lower).
Mobile operation
Where the hot-pressing device is not permanently positioned and is outside its normal working site.
To be able to work without the normal equipment available, the hot-pressing device requires:
A regulating unit PMR-XX that guides the rise in temperature.
The availability of running water or a tank with immersion pump working in manual mode.
A portable manual mode air compressor.
D.5.2
Working cycles
The hot-pressing device's working cycles are as follows.
This manual describes the hot-pressing device only. For the use of the regulating unit (PMR-XX) and the
cooling unit (PMC-XX) see their own manuals.
D.5.3
Stationary operation use
Check the working procedures for the belt/tape, check technical guidelines of the joining method and the
individual Joining Data Sheet of the product.
Open the two locking spindels (2), flip them downwards and lift the upper part of the press (1). When
opening the rods make sure not to put them down heavily on the floor or supporting surface.
Position the belt as required on the heat equalizing plate (5) and clamp it, making sure it is flat.
Position the upper part of the press (1) onto the lower part of the press (3) with the belt fastened to the
heat equalizing plate (5) and the required inserts.
Hot-pressing device PM-306/160