STEP 5
Clean the machined surfaces of the rotary.
Note:
Use a pH-neutral degreaser. For example: WD-40,
Sunnyside Odorless Mineral Spirits, or Benz Oil Sta-brite 306.
Release
[EMERGENCY STOP]
.
Jog the X and Y axis to the Home position.
Disconnect the rotary air hose from the air supply.
Remove the shipping plate [2] from the cable clamp [1]. Discard the
shipping plate.
Install the cable clamp on the enclosure. Use (1) of the 1/4-20 x 2"
thumbscrews [3]. Leave the thumbscrew loose.
Note:
The cable clamp mounting holes [4] are in different
locations on some machines.
STEP 6
Push
[EMERGENCY STOP]
.
Push
[POWER OFF]
.
Set the main circuit breaker to the
OFF
position.
Lock the main circuit breaker. Use an approved lock with an approved safety tag.
STEP 7
Put the rotary air hose into the enclosure through the front door.
Put the air hose through the hole in the top of the enclosure near the
cable clamp you installed in Step 5.
Put the cable along the side of the machine to the bottom.
For CALM [1] machines, connect the air hose to the machine in the CALM
cabinet.
For Pre-CALM [2] machines, connect the air hose to the machine below
the control cabinet.
Copyright 2020 by Haas Automation, Inc. No unauthorized reproduction | Last Published On December 13, 2016