Haas Automation, Inc. | www.HaasCNC.com | 800-331-6746
HSF-325
USER’S GUIDE
2. Select the operating function
At startup, the machine will remain in standby until a mode is selected. Use
the [
< >
] keys to select the Manual or Auto function, and then push the
Enter
key to select the highlighted function.
3. Manual Function:
In
Manu.
mode, push and hold the Manual Heating Button (13) to start
heating. Heating will stop when the button is released. The red LED will turn
on during heating, and the LCD display will count the heating time until the
button is release, or after 10 seconds.
Push the
Cooling
key to start the air blast cooling; push the
Stop
button to
turn off the air blast.
! Notice:
This machine has a fast heating capacity! The maximum
recommended heating temperature is 400°C. Temperatures higher than 400°C
may damage the toolholders.