4.2 Make sure to clean off any oil on the toolholder or cutting tool prior to use.
The heating procedure will carbonize any residual oil and make it more
difficult to remove the cutting tool. For cleaning off oil, we recommend
using a clean rag/cloth or solvent tank.
5.
DO NOT turn on the induction heating head without a toolholder present!
To prevent damage to the machine, do not turn on and heat up the induction
head when a toolholder is not present. Prior to removing the toolholder
during the heating procedure, please press STOP to turn off the machine, to
avoid heating without an object present.
6. After a certain period of use, if you discover that the induction head is
deformed or has turned a darker color (initially, it is white), this could be
the result of the head producing too much heat (above 400°C). Reduce the
heating cycle, and service the head, as needed.
7. This machine uses a
high-voltage power source
. Do not dismantle and
service this machine unless properly trained. To ensure safe operation and
reduce electromagnetic interference, make sure an appropriate
ground
wire
is properly installed. If you are experiencing issues, contact your local
HFO for service.
8.
DO NOT
approach or operate this machine if you are wearing a
pacemaker
or other device that can be affected by electromagnetism.