GB
20
F023
A. Flame temperature sensor
defective or not connected
A. Contact service department
F024
A. Flame temperature sensor at
bottom defective or not connected
A. Contact service department
F026
A. Pellet tank empty
B. Burner not lying flush
C. Burner dirty
D. Pellet fuel has too low a
calorific value
E. Downpipe / screw conveyor
blocked
F. Room too airtight – required
combustion air cannot flow into
the room
G. Flame temperature sensor
defective
H. Screw motor defective
A. Fill pellet tank
B. Position burner correctly
C. Check burner/ clean burner
D. Switch to high quality pellet
type
E. Clean the intake on the screw
conveyor housing with a vacuum
cleaner.
F. Ensure adequate combustion
air - Connect stove with outside
air
G. Flame temperature sensor
defective - contact service
department
H. Screw motor defective -
contact service department
F027
A. Burner dirty
B. Burner not lying flush
C. Door not sealed properly
A. Clean burner
B. Position burner correctly
C. Check seal on door
F028
A. Burner / combustion chamber
dirty
B. Flame temperature sensor at
bottom defective
A. Clean burner
B. Contact service department
F033
A. No WLAN connection
B. WLAN code is incorrect
C. No IP address received
A. Check WLAN reception
B. Check WLAN code
C. Check DHCP settings on the
router
F034
A. No internet connection
available
A. Check internet connection
F040
A. Combustion chamber not
cleaned in specified time interval
A. Clean burner and combustion
chamber – the combustion
chamber door must be opened in
"OFF" operating status. The
burner and combustion chamber
are carefully cleaned using an ash
vacuum cleaner. The combustion
chamber door must be opened for
longer than 60 seconds here so
that the error message is
automatically cleared.
F041
A. Maintenance interval exceeded
A. Clean the flues
F050
A. The spare battery empty
A. Replace the battery of the
control system (CR 2032)
F060
A. The faults in the factory
adjustment have been recorded
A. Contact service department
F1000
A. Restart of the hardware
A. The device is without to power
supply - error message in the
Record of defects