![HAAS + SOHN Catania Installation And Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/haas-sohn/catania/catania_installation-and-operating-instructions-manual_3121051008.webp)
8
5.8. Switching off
– operating status OFF
Procedure:
Press the left key on the operator console until the
information screen appears.
Press the right key (Menu), then move the cursor to
Operating Mode with the two middle keys
– press the
right key (Select)
– move the cursor to “OFF” operating
mode with the two middle keys
– press the right key
(Save).
The stove initiates the Cooling down operating status
and can no longer switch to Heating mode by itself, even
if the room temperature falls below the set room
temperature.
During OFF operating status, the operator console and
parts of the control system continue to be supplied with
power. (About 9 Watts per hour).
5.9. Power cut
The control unit has a backup battery so that the data
are retained during a power cut.
A distinction is made between a short power cut and a
long power cut.
Short power cut
– duration of the power cut shorter than
30 seconds:
Once the electricity supply has been restored, the stove
continues its operation from where it was before the
power cut.
Long power cut
– duration of the power cut longer than
30 seconds:
Once the electricity supply is restored, the stove
switches to Safety shutdown operating status.
A small amount of flue gas may escape during a power
cut.
5.10. Overheating
If the maximum permitted flue gas temperature is
exceeded, a safety shutdown is initiated and the
following error message is shown on the display:
“Shutdown flue gas temperature in Heating mode too
high”.
The stove cannot restart its heating mode until the error
message has been cleared on the operator console and
the desired operating mode has been reset.
5.11. Low temperature shutdown
If during the Heating mode operating status the stove
cools down below a minimum temperature, a safety
shutdown is initiated and the following error message is
shown on the display:
“Shutdown flue gas temperature heating mode too low”
The stove cannot restart its heating mode until the error
message has been cleared on the operator console and
the desired operating mode has been reset.
6. Description of operator console keys
6.1. Operator console
As can be seen in the figure, the display is divided into
five areas.
The screen title contains the name of the relevant
screen which the operator is currently in. On the same
line, right justified is shown the screen number.
In the Menu/Info area there are four columns with 21
characters each available for the text display.
In the information screens, the operator switches
between individual information screens with keys 2 and
3.
If the operator is in the Selection menu, he will be shown
4 submenu items at the same time. He can choose
between the individual menu items with keys 2 and 3,
with the menu item just selected being indicated with a
black background. If key 3 is pressed again after the
selection of the fourth menu item, the operator will be
taken to further selection items (scrolldown menu).
With key 4 the operator selects a menu item and is then
taken to the relevant submenu or, if a parameter is
selected, to the appropriate window in which the
parameter may be adjusted.
Inactive menu items and information:
Inactive menu items are not shown in the selection
menu.
Nor are inactive measurement values shown by the
relevant configuration on the information screens or in
the values information.
Screen title
Screen no.
Description of
left key
Description of
right key
Description of
middle keys
Menü- / Infobereich
Tastenbereich
1
2
3
4
Operating mode
Heating
Operating status
Standby
Target/actual room temp. 20/20°C
Time
Date
Tastenbezeichnungen