![HAAS + SOHN Catania Installation And Operating Instructions Manual Download Page 27](http://html1.mh-extra.com/html/haas-sohn/catania/catania_installation-and-operating-instructions-manual_3121051027.webp)
27
Fire goes out
1. Storage container is empty
Refill storage container
2. The combustion air supply in
the combustion pot is blocked
by ash deposits
Clean burner
3. Pellet container contains too
much dust
Empty pellet container and clean screw
conveyor channel with vacuum cleaner
4. Screw conveyor jamming
1. Pull out the mains plug and move the
screw conveyor motor back and forth,
otherwise 2. empty pellet container and
clean screw conveyor channel with
vacuum cleaner, otherwise 3. call in the
service engineer
5. Flue gas fan defective
Call in the service engineer
Pellet stove shuts off
after about 30
minutes
1. Flue gases have not reached
operating temperature
Check whether there are enough wood
pellets in the combustion pot. Press the
ignition button again.
2. Burner displaced
Clean burner
Flue gas escaping
1. Power cut
Ventilate room
2. Flue tubes or chimney
(fireplace) very dirty
Clean flue tube or chimney (fireplace)