ST, DS - Turret to X Axis Parallelism Correction
This section corrects the parallelism of the turret [1] to the X Axis movement [2], which is set by the alignment of the turret
assembly [3] to the wedge [4].
STEP 1
Refer to
ST, DS - Turret to X Axis Parallelism Check
to measure the
parallelism of the turret to X Axis.