2
<OM>
3.
Execute the
io on CPU 1
command to power on the target switch module.
In this example, the switch module in slot 1 is powered on.
<OM> io 1 CPU on
4.
Execute the
display io list
command to verify that the switch module in slot 1 has been
powered on.
<OM>display io list
Slot : 1
Running status : Normal
UID LED : Off
PSU : On
Management URL : http://192.168.200.1/web/index.html
Product name : BX1010E
CPU usage : 15%
Powering off the switch module
Power-off methods
The switch module supports the following power-off methods.
Table 5 Switch module power-off methods
Power-off method
Application scenario
Together with the server
N/A
From the OM Web interface
The switch module is operating on the server.
From the OM CLI
Procedure
When the switch module is powered off, its health LED is off. For the health LED location on the
module, see "LEDs and buttons."
Powering off the switch module together with the server
The switch module will be powered off automatically when the server is powered off. You are not
required to perform any extra operation.
Powering off the switch module from the OM Web interface
1.
Obtain required information.
Table 6 Obtaining required information
Parameter
Setting
OM management IP
•
Management IP address (default): 192.168.100.100
•
Subnet mask (default): 255.255.255.0
OM username and password
•
Username (default): admin
•
Password (default): Password@_
Slot where the switch module
1