background image

 

<OM> 

3. 

Execute the 

io on CPU 1

 command to power on the target switch module. 

In this example, the switch module in slot 1 is powered on. 

<OM> io 1 CPU on 

4. 

Execute the 

display io list

 

command to verify that the switch module in slot 1 has been 

powered on. 

<OM>display io list 

 Slot : 1 

      Running status   : Normal 

      UID LED          : Off 

      PSU              : On 

      Management URL   : http://192.168.200.1/web/index.html 

      Product name     : BX1010E 

      CPU usage        : 15% 

Powering off the switch module 

Power-off methods 

The switch module supports the following power-off methods. 

Table 5 Switch module power-off methods 

Power-off method 

Application scenario 

Together with the server 

N/A

 

From the OM Web interface 

The switch module is operating on the server. 

From the OM CLI 

 

Procedure 

When the switch module  is powered off, its health LED is off. For the health LED location on the 
module, see "LEDs and buttons." 

Powering off the switch module together with the server 

The switch module  will be powered off automatically when the server is powered off. You are not 
required to perform any extra operation. 

Powering off the switch module from the OM Web interface 

1. 

Obtain required information. 

Table 6 Obtaining required information 

Parameter 

Setting 

OM management IP 

 

Management IP address (default): 192.168.100.100 

 

Subnet mask (default): 255.255.255.0 

OM username and password 

 

Username (default): admin 

 

Password (default): Password@_ 

Slot where the switch module 

Summary of Contents for UniServer BX1010E

Page 1: ...H3C UniServer BX1010E Switch Module User Guide New H3C Technologies Co Ltd http www h3c com Document version 6W100 20230224...

Page 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Page 3: ...choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional s...

Page 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Page 6: ...SOL serial port redirection 1 Configuring a management IP address for the switch module 1 Obtaining and planning related data 1 Configuring a management IP address from the OM Web interface 2 Configu...

Page 7: ...burnt allow the module and its internal modules to cool before touching them For adequate heat dissipation of the server install a filler panel in the slot if the module is not installed Electrical s...

Page 8: ...prevent electrostatic discharge The following are grounding methods that you can use to prevent electrostatic discharge Wear an ESD wrist strap and make sure it makes good skin contact and is reliably...

Page 9: ...le is a type of interconnect module and is also called interconnect module in this document Tools Table 1 lists the tools that you might use when replacing the switch module Table 1 Tools Picture Name...

Page 10: ...welry and watches Backup the switch module configuration Examine the slot and connector for damages Make sure the pins are not damaged bent for example and do not contain any foreign objects Be clear...

Page 11: ...t from the chassis 2 Place the switch module into an antistatic bag 3 Take the new switch module from the antistatic bag 4 Press the release button on the new switch module to fully open the ejector l...

Page 12: ...been installed on the server before the server is powered on it will power on automatically when the chassis is powered on You are not required to perform any extra operations If you install the swit...

Page 13: ...and log in to the OM CLI Table 4 SSH login parameters Parameter Setting Protocol SSH Port number 22 OM management IP Management IP address default 192 168 100 100 Subnet mask default 255 255 255 0 OM...

Page 14: ...ogether with the server N A From the OM Web interface The switch module is operating on the server From the OM CLI Procedure When the switch module is powered off its health LED is off For the health...

Page 15: ...ogin Figure 2 Logging in to the OM Web interface 3 Perform the following operations to power off the switch module a Click Interconnect Module Management b Select the target switch module c Click Virt...

Page 16: ...Co Ltd All rights reserved Without the owner s prior written consent no decompiling or reverse engineering shall be allowed OM 3 Execute the io 1 CPU off command to power off the target switch module...

Page 17: ...ng the switch module from the SYS serial port console port Prerequisites The switch module has been powered on For information about powering on the switch module see Powering on the module You have c...

Page 18: ...sol connect io 1 Begin to edit commands Sysname Jul 29 13 42 35 975 2013 H3C SHELL 5 SHELL_LOGIN Console logged in from c on1 Sysname NOTE After accessing the switch module CLI through SOL serial por...

Page 19: ...configuration file before clicking OK Configuring a management IP address from the OM CLI Prerequisites The switch module has been powered on For information about powering on the switch module see P...

Page 20: ...1 through Twenty FiveGigE 1 1 9 4 You can split 100 GE interface HundredGigE 1 1 9 into four 10 GE interfaces Ten GigabitEthernet 1 1 9 1 to Ten GigabitEthernet 1 1 9 4 If you need higher bandwidth o...

Page 21: ...2 Enter system view Sysname system view 3 Enter the view of any breakout interface If the 100 GE interface is split into 25 GE breakout interfaces execute the interface twenty fivegige command to ente...

Page 22: ...module You have accessed the switch module For information about accessing the switch module see Accessing the switch module Procedure 1 Access user view of the switch module at the CLI Execute the d...

Page 23: ...192 168 1 1 put flash uis cmw710 boot 1 00 10 bin Press CTRL C to abort Total Received Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 5572k 0 0 100 5572k 0 832k 0 0...

Page 24: ...hown by callout 1 in Figure 4 open your browser on the your PC and enter the OM Web management IP in the format of https OM_ip_address b As shown by callout 2 in Figure 4 enter the username and passwo...

Page 25: ...e LAN Make sure the PC and OM module management network are reachable to each other at Layer 3 Figure 5 Setting up the environment for accessing the OM CLI 2 Log in to the OM CLI a As shown by callout...

Page 26: ...efault 192 168 100 100 Subnet mask default 255 255 255 0 OM username and password Username default admin Password default Password _ By default SSH access to OM CLI is enabled Data in this table is us...

Page 27: ...0 Upgrading firmware For information about the firmware upgrade procedure see H3C UniServer B16000 Blade Server Upgrade Guide...

Page 28: ...lation guidelines 7 Internal connections 9 Switch module and mezzanine network adapter connections 9 Switch module and mezzanine network adapter port connections 11 Hardware compatibility 12 Mezzanine...

Page 29: ...rovides data switching for the blade servers It also provides external data ports to connect the blade servers to the external network Figure 1 BX1010E switch module High availability The switch modul...

Page 30: ...on 80 W Environment Temperature Operating 5 C to 45 C 41 F to 113 F Storage 40 C to 70 C 40 F to 158 F Humidity Operating 8 to 90 noncondensing Storage 5 to 95 noncondensing Altitude Operating 60 m to...

Page 31: ...the IRF member ID for a device execute the irf member renumber command B Differentiates between internal and external ports 0 represents an internal port and 1 represents an external port C Number of...

Page 32: ...on For the transceiver module and cables available for the switch module and their specifications see Transceiver module and cables available for the switch module For information about splitting a 10...

Page 33: ...is used as a single port the LED nearest to it indicates its status The other three LEDs are off If a 100 GE fiber port is split into four interfaces each of the four LEDs indicates the operating sta...

Page 34: ...is present on the port and the port rate is 100 Gbps and data is being transmitted or received on the port Steady yellow A link is present on the port and the port rate is 40 Gbps but no data is bein...

Page 35: ...responsible for internal and external data forwarding and report of unrecognized packets Figure 5 Logical architecture Installation guidelines Follow these guidelines when you install switch modules...

Page 36: ...8 Figure 6 Switch module installation slots 1 ICM1 slot 2 ICM2 slot 3 ICM3 slot 4 ICM4 slot 5 ICM5 slot 6 ICM6 slot...

Page 37: ...etween the mezzanine network adapter slots and switch module slots For the specific locations of the mezzanine network adapter slots and switch module slots see the marks on the modules H3C UniServer...

Page 38: ...re collected as follows Network adapter embedded in the system board connected to the active and standby OMs Mezzanine network adapters 1 and 4 connected to switch modules in slots 1 and 4 Mezzanine n...

Page 39: ...and mezzanine network adapter port connections Before configuring mezzanine network adapters on the blade server identify the connections between the mezzanine network adapter ports and switch module...

Page 40: ...Mb 2 25G 2 2 port 25Gb converged mezzanine network adapter Transceiver module and cables available for the switch module The following tables describe the transceiver module and cables available for t...

Page 41: ...G FC fiber port transceiver module Table 9 Transceiver module and cables available for the switch module 3 Transceiver module cable model Central wavelengt h Connec tor Fiber cable specifications Max...

Page 42: ...25 m MMF 150 m 492 13 ft QSFP 40G SR4 MM850 50 125 m MMF 150 m 492 13 ft QSFP 40G CSR4 MM85 0 CM 50 125 m MMF 400 m 1312 34 ft QSFP 40G SR4 MM850 50 125 m MMF 400 m 1312 34 ft QSFP28 transceiver modul...

Page 43: ...3M N A N A QSFP28 copper cable 3 m 9 84 ft QSFP 100G D CAB 3M CM 3 m 9 84 ft QSFP28 to 4 SFP28 copper cables QSFP 100G 4SFP 25G CAB 3M CM N A N A QSFP28 to 4 SFP28 copper cable 3 m 9 84 ft QSFP 100G 4...

Page 44: ...ules User Guide H3C transceiver modules and cables are subject to change over time For the most up to date list of H3C transceiver modules and cables contact H3C Support or marketing staff Always wear...

Page 45: ...H3C Support Before contacting H3C Support collect the following server information to facilitate troubleshooting Log and sensor information Product serial number Product model and name Snapshots of e...

Page 46: ...o ensure that hardware at the end of its life is recycled Vendors with product recycling qualification are contracted to New H3C to process the recycled hardware in an environmentally responsible way...

Page 47: ...able module can be installed or removed while the server is running without affecting the system operation Redundancy A mechanism that ensures high availability and business continuity by providing ba...

Page 48: ...C CLI Command line interface F FC Fiber Channel FCoE Fibre Channel over Ethernet FCF FCoE Forwarder I ICM Interconnect module IRF Intelligent Resilient Framework M Mezz Mezzanine N NPV N_Port Virtuali...