Powering on and powering off the module
Powering on the module
Power-on methods
The switch module supports the following power-on methods.
Table 2 Switch module power-on methods
Power-on method
Application scenario
Together with the server
•
The switch module is installed on the server before
the server is powered on.
•
The switch is installed on the server after the server is
powered on.
From the OM Web interface
The switch module is installed on an operating server and
the module is powered off (the heath LED on the module is
off).
From the OM CLI
Procedure
When power is present on the switch module, its health LED is steady green. For the health LED
location on the module, see "LEDs and buttons."
Powering on the switch module together with the server
•
If the switch module has been installed on the server before the server is powered on, it will
power on automatically when the chassis is powered on. You are not required to perform any
extra operations.
•
If you install the switch module on an operating server, it will power on automatically. You are
not required to perform any extra operations.
Powering on the switch module from the OM Web interface
1.
Obtain required information as described in
Table 3 Obtaining required information
Parameter
Setting
OM management IP
•
Management IP address (default): 192.168.100.100
•
Subnet mask (default): 255.255.255.0
OM username and password
•
Username (default): admin
•
Password (default): Password@_
Slot where the switch module
resides
1
Data in this table is used as an example.
2.
Log in to the OM Web interface.
a.
As shown by callout 1 in
, open your browser on your PC and enter the OM Web
management IP (in the format of https://
OM_ip_address
)
b.
As shown by callout 2 in
, enter the username and password.