Trap 1.3.6.1.4.1.25506.8.35.12.1.16<hh3cBoardTemperatureHigher>: chassisIndex is 0,
slotIndex 0.0
%Dec 7 11:49:20:444 2011 H3C DEVM/4/BOARD_TEMP_TOOHIGH: Board temperature is too high
on Chassis 0 Slot 0, type is SR6602-X2.
After the router runs for a period of time, the environmental temperature of the router will drop below
the high temperature threshold, and the following information appears on the configuration terminal:
%Dec 7 11:50:11:436 2011 H3C DRVMSG/3/TEMP_NOWARNING:
Environment temperature recovered from TEMP_WARNING in Slot 0, index is 1.
%Dec 7 11:50:11:436 2011 H3C DRVMSG/3/TEMP_SYSNOWARNING:
System temperature recovered from TEMP_WARNING.
#Dec 7 11:50:13:244 2011 H3C DEVM/1/BOARD TEMPERATURE NORMAL:
Trap 1.3.6.1.4.1.25506.8.35.12.1.17<hh3cBoardTemperatureFormHigherToNormal>:
chassisIndex is 0, slotIndex 0.0
%Dec 7 11:50:13:244 2011 H3C DEVM/5/BOARD_TEMP_NORMAL: Board temperature changes to normal
on Chassis 0 Slot 0, type is SR6602-X2.
When the environmental or CPU temperature of a module exceeds the critical temperature threshold,
the ALM LED of the router is red.
%Dec 7 11:17:01:436 2011 H3C DRVMSG/3/TEMP_ALARM:
CPU temperature is greater than alarm upper limit in slot 0, index is 0.
To view the high temperature threshold and critical temperature threshold of each module, use the
display environment
command.
To troubleshoot the cooling system failure:
1.
Check whether the fans are running properly.
2.
Check whether the working environment of the module is well ventilated.
3.
Use the
display environment
command to check whether the temperature in the module
keeps rising.
4.
If the temperature inside the module still reaches the critical temperature threshold, power off
the router immediately and contact your local sales agent.
NOTE:
For more information about the
display environment
command, see
H3C SR6600 Router Series
Fundamentals Command Reference
.
Interface module, cable, and connection failure
After an HIM/MIM is installed and the router is powered on, the LEDs on the HIM/MIM panel may
indicate abnormal operation.
To solve this problem:
1.
Check whether the HIM/MIM cable is correctly selected.
2.
Check whether the HIM/MIM cable is correctly connected.
3.
Use the
display
command to check whether the interface of the interface module has been
correctly configured and is working properly.