121
Hardware ToD
input or output compatibility
SR6604-X/SR6608-X/SR6616-X
Yes
To use a ToD clock, you must configure ToD input or output:
•
ToD input
—The device obtains clock signals from an external ToD clock and synchronizes ToD to all
devices in the PTP network.
•
ToD output
—The device operates as a ToD clock to synchronize ToD to other devices.
To implement more accurate time synchronization, you can specify a delay correction value.
To configure ToD input or output:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure ToD input or output.
ptp
{
tod0
|
tod1
} {
input
[
delay
input-delay-time
] |
output
[
delay
output-delay-time
] }
By default:
•
The device receives signals
from an external ToD clock.
•
The delay correction value for a
ToD clock is 0 nanoseconds.
Configuring ToD clock parameters
The following matrix shows the ToD clock parameters and hardware compatibility:
Hardware ToD
clock
parameters compatibility
SR6602-X No
SR6604/SR6608/SR6616
No
SR6604-X/SR6608-X/SR6616-X
Yes
To configure ToD clock parameters:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Configure ToD clock
parameters.
ptp clock-source
{
tod0
|
tod1
}
{
accuracy
acc-value
|
class
class-value
|
time-source
ts-value
}
By default, the time accuracy is 32,
the time class is 6, and the attribute
value is 32 for a ToD clock.
Configuring a priority for a clock
Step Command
Remarks
1.
Enter system view.
system-view