26
If the following information is displayed, the system image is missing. You must manually
download the system image.
Loading the main image files...
Loading file cfa0:/boot.bin.................................................
...................................Done.
<boot>
If one of the following symptoms appears, contact H3C Support:
−
The system stops at the "System image is starting..." message.
−
After displaying the "System image is starting..." message, the system does not enter
the CLI but repeatedly reboots.
−
The system displays the "Press ENTER to get started" message but you cannot enter
the CLI by pressing
Enter
.
−
You can enter the CLI but the system reboots after a while.
LPU startup failure
Symptom
The LPU cannot start up correctly.
Solution
To resolve the problem:
1.
Check the RUN LED on the LPU.
If the LED flashes at the frequency of 8 Hz, or the LED flashes over 5 seconds and then
goes off, the LPU has started up correctly.
If the LED flashes at the frequency of 1 Hz or is always on, the LPU has hardware problems.
Go to step
If the LED is always off, the LPU has not been powered on or the LPU has a problem. Go to
step
2.
If the LED is always off, verify that the LPU has been powered on:
a.
Identify whether the LPU has been powered on.
<System>display device
Slot No. Board type Status Primary SubSlots
---------------------------------------------------------------------
0 RSE-X3 Startup Standby 0
1 RSE-X3 Normal Master 0
2 N/A Absent N/A N/A
3 FIP-300 Wait N/A 1
The values for the
Status
field include:
−
Normal
—The LPU is operating correctly.
−
Startup
—The LPU has been powered on and is starting up.
−
Wait
—The LPU has not been powered on.
b.
If the LPU has not been powered on, identify whether the available power is sufficient.
[System-probe]display hardware internal sysm power-management
System Power Total : 650 watts
System Power Used : 150 watts