6
speed 10000
duplex full
dldp enable
#
interface Ten-GigabitEthernet1/0/2
speed 10000
duplex full
dldp enable
#
•
The configuration file for Device B is the same as Device A. (Details not shown.)
Example: Manually shutting down
unidirectional links
Network requirements
As shown in
, Device A and Device B are connected through two fiber pairs.
Configure DLDP on the devices to meet the following requirements:
•
Each device can detect unidirectional links caused by cross-connected fibers or a
disconnected fiber.
•
When a unidirectional link is detected, the administrator can manually shut down the faulty
port based on the connection status of the link.
•
The interface recovers from failure after the administrator clears the fault and manually brings
up the port.
Figure 3 Network diagram
Software version used
This configuration example was created and verified on S6300-CMW710-R2310.
Configuration restrictions and guidelines
When you configure DLDP, follow these restrictions and guidelines:
•
For DLDP to operate correctly, configure the full duplex mode for the interfaces at the two ends of
the link, and configure the same speed for the two interfaces.
•
For DLDP to operate correctly, enable DLDP on both sides and make sure the following settings are
consistent:
{
Interval to send Advertisement packets.