22
Connecting the power cord
CAUTION:
•
The AC power cord for the PSR150-A1 uses C13 connector, while the AC power cord for the
PSR360-56A/PSR720-56A/PSR1110-56A uses high-temperature C15 connector. Do not mix them.
•
Provide a circuit breaker for each power module and make sure the circuit breaker is off before installation.
Table 5 Power cord connection procedures at a glance
Switch
Power mode
Connection procedure reference
S5150X-16ST-EI
AC input
Connecting an AC power cord to the switch
+12 VDC RPS input
(RPS800-A)
Connecting a DC power cord to the switch
S5150X-16S-EI
PSR150-A1
PSR150-D1: –48 VDC input
(External RPS power module:
RPS800-A or RPS1600-A)
S5150-24S-PWR-EI
PSR360-56A
PSR720-56A
PSR1110-56A
Connecting the
PSR360-56A/PSR720-56A/PSR1110-56A
Connecting an AC power cord to the switch
To connect an AC power cord to a switch that uses fixed power modules:
1.
Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2.
Attach the hooks of the bail latch into the holes on the two sides of the AC-input power
receptacle, and pull the bail latch upwards (see
3.
Connect one end of the AC power cord to the AC-input power receptacle on the switch (see
callout 1 in
4.
Pull the bail latch down to secure the plug to the power receptacle (see callout 2 in
).
5.
Connect the other end of the power cord to the AC power outlet.
Figure 31 Connecting an AC power cord to the switch (1)
Summary of Contents for S5150-EI Series