Operation Manual – NQA
H3C S3610&S5510 Series Ethernet Switches
Chapter 1 NQA Configuration
1-20
2)
Configure the NQA client
Follow these steps to configure NQA client for the TCP test:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable the NQA client
nqa-agent enable
Required
Create an NQA test group
and enter its view
nqa
admin-name
operation-tag
—
Set the test type to TCP
test-type
{
tcpprivate
|
tcppublic
}
Required
Configure a destination
address for a test
destination-ip
ip-address
Required
The destination address
must be the listening IP
address on the NQA
server.
Configure a destination
port
destination-port
port-number
If the test type is
TCP-Public, no port
needs to be configured. If
the test type is
TCP-Private, a port must
be configured and it must
be the listening port
configured on the NQA
server.
Configure common
optional parameters
Configuring Optional
Parameters for NQA
Tests
Optional
Enable the NQA test
test-enable
Required
View the test results
display nqa results
[
admin-name
operation-tag
]
Required
Available in any view.
II. Configuration example
1) Network
requirements
Use the NQA TCP-Private function to test the time for setting up a TCP connection
between the local port (Switch A) and the specified destination port (Switch B). The port
number used is 9000.