3
•
1 × USB port (USB 3.0, host port)
•
1 × 1PPS/ToD time synchronization port
•
2 × SMB clock input ports
•
2 × SMB clock output ports
Transmission rate
•
Console port: 9600 bps (default) to 115200 bps
•
10/100/1000BASE-T port: 10/100/1000 Mbps
•
SFP port: 1000 Mbps
NOTE:
•
To verify compatibility of the card with the software release you are using, see the release notes.
•
The USB port outputs power as prescribed by USB 2.0. You can only install a USB 2.0-compliant
device in the USB port.
•
Set the same speed and duplex mode for a management Ethernet interface and its peer port.
•
If multiple management ports are connected to one remote switch, you must assign their peer
ports to different VLANs on the remote switch. Login or file transfer will fail if the peer ports are in
the same VLAN.
•
When using the BootWare menu to upgrade software or BootWare, make sure you use the
correct port for image transferring.
LSXM1SUPB1, LSXM1SUPE1, LSXM1SUP04B1, or LSXM1SUP04H1 MPU
—Use management
port M0/0/3.
LSXM1SUPA1, LSXM1SUPH1, or LSXM2SUPT1 MPU
—Use 10/100/1000BASE-T port M0/0/0.
Cloud supervisor engine unit
The LSXM1X86SUPE1 cloud supervisor engine unit (SEU) contains a switching control unit and an
X86 server unit. The switching control unit is the core of control and switching for the device. The X86
server unit is designed for applications such as virtualization and database to meet IDC and cloud
computing requirements.
Table 5 LSXM1X86SUPE1 specifications
Item
Specification
Processor
•
Switching control unit: MIPS64 (four cores), 1.2 GHz
•
X86 server unit: Intel Xeon E5-26xx V3, 2.6 GHz
SDRAM
•
Switching control unit: 16 GB DDR3 SDRAM (two DIMM slots)
•
X86 server unit: 64 GB DDR4 SDRAM (four DIMM slots)
Flash
•
Switching control unit: 1 GB (NAND flash)
•
X86 server unit:
256 GB (SSD)
4 GB (NAND flash, for the BMC service)
4 GB (NAND flash, for the USB service)
NVRAM
•
Switching control unit: 512 KB
•
X86 server unit: 1 MB
Connector
•
RJ-45
•
LC
•
Type A USB