34
15 Absent -- -- -- -- --
16 Absent -- -- -- -- --
<H3C>
Execute the
display alarm
command to view alarm information about the power module.
<H3C>display alarm
Slot CPU Level Info
- - INFO Power 1 is absent.
- - INFO Power 2 is absent.
- - INFO Power 3 is absent.
- - INFO Power 4 is absent.
- - INFO Power 5 is absent.
- - INFO Power 6 is absent.
- - INFO Power 7 is absent.
- - INFO Power 8 is absent.
- - INFO Power 9 is absent.
- - INFO Power 10 is absent.
- - INFO Power 12 is absent.
- - INFO Power 13 is absent.
- - INFO Power 14 is absent.
- - INFO Power 15 is absent.
- - INFO Power 16 is absent.
<H3C>
If the power module is in
Absent
. If the power module is in
Faulty
state, go to
step
2.
Verify that the power module is installed securely.
a.
Remove and reinstall the power module to make sure the power module is installed
securely. Then execute the
display power
command to verify that the power module has
changed to
Normal
state.
b.
Remove and install the power module into an empty power module slot. Then execute the
display power
command to check the power module state. If the power module remains
in
Absent
state, go to step
3.
Verify that the power module is operating correctly.
a.
Verify that the power module is connected to the power source correctly. If it is not, connect
it to the power source correctly. Then execute the
display power
command to verify that
the power module has changed to
Normal
state.
b.
Remove and install the power module into an empty power module slot. Then execute the
display power
command to check the power module state. If the power module remains
in
Faulty
state, go to step
4.
If the issue persists, contact H3C Support.
Fan tray failure
Symptom