background image

Manual version: 6PW102-20170411 

BOM: 3123A0T2

 

ii 

Item Specification 

Dimensions (H × W × D) 

40.1 × 399.2 × 512 mm (1.58 × 15.72 × 20.16 in) 

Power consumption 

190 to 260 W 

Weight 

5.8 kg (12.79 lb) 

Hot swapping 

Supported 

Ports 

 

1 console port 

 

2 USB ports ((not supported by the card software) 

 

2 combo interfaces, which can operate in 10/100/1000BASE-T copper 

port mode or 1000BASE-X SFP fiber port mode at a time. 

You can use the 

combo

 

enable

 { 

copper 

fiber 

} command to activate either 

port. By default, the copper combo port is activated. 

Ambient temperature 

 

Operating: 0°C to 45°C (32°F to 113°F) 

 

Storage: –40°C to +70°C (–40°F to +158°F) 

Ambient humidity 

 

Operating: 5% RH to 95% RH, noncondensing 

 

Storage: 5% RH to 95% RH, noncondensing 

Compatible device models  

 

H3C S12500-X series switches 

System software version 

See the release notes that come with the card. 

 

Table 2 Console port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

RS-232 

Transmission baud rate 

9600 bps (default) to 115200 bps 

Transmission medium 

Asynchronous serial cable 

Transmission distance 

15 m (49.21 ft) 

Services 

 

Provides connection to an ASCII terminal. 

 

Provides connection to the serial port of a local or remote (through a pair 

of modems) PC running terminal emulation program. 

 

Supports command line interface (CLI) 

 

Table 3 10/100/1000BASE-T copper port specifications 

Item Specification 

Connector RJ-45 

Interface standard 

802.3, 802.3u, and 802.3ab 

Interface type 

MDI/MDIX autosensing 

Supported cable 

Category-5 (or above) twisted pair cable 

Transmission distance 

100 m (328.08 ft) 

Port transmission rate 

 

10 Mbps, half/full duplex 

 

100 Mbps, half/full duplex 

 

1000 Mbps, full duplex 

 

Summary of Contents for S12500-X

Page 1: ...messages Failover interface for stateful failover 3 Specifications Figure 1 Front panel 1 Console port CONSOLE 2 USB ports hardware reserved software not support currently 3 10 100 1000BASE T copper combo port 4 10 100 1000BASE T copper combo port LED LINK ACT 5 1000BASE X fiber combo port 6 1000BASE X fiber combo port LED LINK ACT 7 Alarm LED ALM 8 System LED RUN 9 Ejector lever 10 Captive screw ...

Page 2: ...e models H3C S12500 X series switches System software version See the release notes that come with the card Table 2 Console port specifications Item Specification Connector RJ 45 Interface standard RS 232 Transmission baud rate 9600 bps default to 115200 bps Transmission medium Asynchronous serial cable Transmission distance 15 m 49 21 ft Services Provides connection to an ASCII terminal Provides ...

Page 3: ... 86 miles SFP GE LH80 SM1550 1550 nm LC 9 125 μm single mode optical fiber 80 km 49 71 miles SFP GE LH100 SM1550 1550 nm LC 9 125 μm single mode optical fiber 100 km 62 14 miles 4 LEDs The card provides LEDs to show the operating status of the card and interfaces Table 6 LED description LED Status Description Alarm LED ALM Off The system is operating correctly Steady red The system is in an alarm ...

Page 4: ...ted components facing left Pull the ejector levers outward and then gently push the card in along the slot guide rails until the card is in close contact with the backplane 3 Push the ejector levers inward 4 Tighten the captive screws with a Phillips screwdriver to secure the card in the slot Figure 2 Installing the card 5 2 Removing the card 1 Use a Phillips screwdriver to loosen the captive scre...

Page 5: ...h Series High End Firewalls Configuration Guides To log in to the card from the switch s CLI perform the following task in user view Task Command Remarks Log in to the card through OAP In standalone mode oap connect slot slot number In IRF mode oap connect chassis chassis number slot slot number To return to the CLI interface of the switch press Ctrl K 7 Software upgrade The card uses independent ...

Reviews: