Installation Manual
H3C S3100 Series Ethernet Switches
Chapter 3 Installation
3-4
Model
Physical dimensions
(H × W × D)
Configuration
type of front
mounting ear
Configuration
type of rear
mounting ear
S3100-2
6TP-PW
R-EI
43.6 × 440 × 420 mm
(1.7 × 17.3 × 16.5 in.)
Standard Standard
S3100-1
6TP-PW
R-EI
43.6 × 300 × 260 mm
(1.7 × 11.8 × 10.2 in.)
Optional —
S3100-TP
-PWR-EI
S3100-8
TP-PWR-
EI
43.6 × 300 × 220 mm
(1.7 × 11.8 × 8.7 in.)
Optional —
II. Use front mounting ears to install a switch
Follow these steps to mount a switch into a 19-inch standard cabinet:
1) Wear an ESD-preventive wrist strap to check the grounding and stability of the
cabinet.
2)
Take out the screws which are packed together with the front mounting ears, and
fix one end of mounting ears to the switch, as shown in Figure 3-3.
Front panel
Figure 3-3
Fix front mounting ears (1)
3)
Place the switch horizontally in a proper position, and fix the other end of mounting
ears to the front brackets with screws and captive nuts, as shown in Figure 3-4.