Installation Manual
H3C SecPath F1000-A Firewall
Chapter 1 Product Overview
1-4
LED
Description
ACT
Software running LED:
Blinking means the software is operating normally; OFF means
the software is faulty.
LINK
GE interface LED:
ON means a link is present; OFF means no link is present.
ACTIVE
GE interface LED:
ON means data are being transmitted/received on the interface;
OFF means no packets are being transmitted/received on the
interface.
1.2.4 Attributes of the Fixed Interfaces
I. Console port (CON)
Table 1-3
Attributes of the console port
Attribute
Description
Connector RJ-45
Standard RS-232
Baud rate
1200 bps to 115200 bps, defaults to 9600 bps
Services
Connected to an ASCII terminal
Connected to the serial interface of a local PC running terminal
emulation software
Command line interface (CLI)
II. Auxiliary port (AUX)
Table 1-4
Attributes of the AUX port
Attribute
Description
Connector RJ-45
Standard RS-232
Baud rate
1200 bps to 115200 bps
Services
Modem dial-up
Backup