3.5 Connecting Power Cord and Grounding Wire
3.5.1 Connecting AC Power Cord
I. AC power socket (recommended)
You are recommended to use a mono-phase three-wire power socket with a neutral
point or a multi-function power socket for computers. The neutral point of the power in
your building must be well grounded. Normally, the neutral point of the power supply
system in your building has already been grounded during the construction and wiring;
but you should make sure this is the fact.
Neutral point
Zero line
Live line
Neutral point
Zero line
Live line
Figure 3-20
Recommended AC power socket
II. Connecting AC power cord
1)
Connect one end of the grounding wire (delivered with the switch) to the grounding
screw on the rear of the chassis and the other end to the ground nearby.
2) Connect one end of the power cord to the power socket on the rear panel of the
chassis and the other end to an outside AC power socket.
3)
Install the power cord tie for the AC power cord. Insert the two ends of the power
cord tie into the slots at both sides of the AC power input, and then set the power
cord into the notch of the power cord tie.
(4)
(2)
(3)
(1)
(4)
(2)
(3)
(1)
(1): Rear panel
(2): Slot of power cord tie
(3): AC power cord tie
(4): AC power cord
Figure 3-21
Install AC power cord ties