Operation Manual – HWPing
H3C S5100-SI/EI Series Ethernet Switches
Chapter 1 HWPing Configuration
1-24
4 15891 1 0 2000-04-03 03:59:52.9
5 15772 1 0 2000-04-03 03:59:37.0
6 15653 1 0 2000-04-03 03:59:21.2
7 9792 1 0 2000-04-03 03:59:05.5
8 9794 1 0 2000-04-03 03:58:55.6
9 9891 1 0 2000-04-03 03:58:45.8
10 3245 1 0 2000-04-03 03:58:35.9
For detailed output description, see the corresponding command manual.
Note:
If you are downloading a file from the server, you do not need to specify an FTP
operation type. For details, see section
Configuring FTP test on HWPing client
.
1.3.4 HTTP Test
I. Network requirements
An H3C S5100-SI/EI series Ethernet switch serves as the HWPing client, and a PC
serves as the HTTP server. Perform a HWPing HTTP test between the switch and the
HTTP server to test the connectivity and the time required to download a file from the
HTTP server after the connection to the server is established.
II. Network diagram
Figure 1-5
Network diagram for the HTTP test
III. Configuration procedure
z
Configure HTTP Server:
Use Windows 2003 Server as the HTTP server. For HTTP server configuration, refer to
the related instruction on Windows 2003 Server configuration.
z
Configure HWPing Client (Switch A):
# Enable the HWPing client.
<Sysname> system-view
[Sysname] hwping-agent enable