3
Mode 3: The switch module is powered on through the OM CLI.
1.
Set the SSH login parameters and log in to the OM CLI using the remote access software.
Table 12 SSH login parameters
Login parameters
Data
Protocol
SSH
Port number
22
Management IP address of the OM module
•
Management IP address (default):
192.168.100.100
•
Subnet mask (default): 255.255.255.0
User name and password used to log in to the
OM module
•
User name (default): admin
•
Password (default): Password@_
•
The SSH access mode is enabled for the OM module by default.
•
The data marked "default" are configured before factory delivery.
•
The data in the table is for illustration only. The actual data during on-site operations shall prevail.
2.
After login, the OM CLI displays the login page, as shown below.
******************************************************************************
* Copyright (c) 2004-2019 New H3C Technologies Co., Ltd. All rights reserved.*
* Without the owner's prior written consent, *
* no decompiling or reverse-engineering shall be allowed. *
******************************************************************************
<OM>
3.
Run
psu-io on io 1
to power on the switch module in slot 1.
<OM> psu-io on io 1
4.
Run
display io list
to check whether the switch module in slot 1 is powered on.
<OM>display io list
Slot : 1
Running status : Normal
UID LED : Off
PSU : On
Management URL : http://192.168.200.1/web/index.html
Product name : BX720E
CPU usage : 15%
Powering off the switch module
This section describes how to power off the switch module.
Supported power-off modes