ii
Common operations ··········································································································································· 7
Logging in to the Web UI of the OM module ······························································································ 7
Logging in to the CLI of the OM module ···································································································· 8
Firmware upgrade·························································································· 1
Page 1: ...ols 1 Preparations 2 Replacement procedure 2 Powering on and powering off 1 Powering on the switch module 1 Supported power on modes 1 Operation methods 1 Powering off the switch module 3 Supported po...
Page 2: ...ii Common operations 7 Logging in to the Web UI of the OM module 7 Logging in to the CLI of the OM module 8 Firmware upgrade 1...
Page 3: ...ly through conductive objects to prevent electric shock Safety precautions When maintaining the device place the device on a clean stable table or floor To avoid personal injury from hot surfaces or i...
Page 4: ...ods to prevent electrostatic discharge Wear an ESD wrist strap and ensure that it is reliably grounded Ensure that the ESD wrist strap makes good skin contact and can be flexibly stretched out and dra...
Page 5: ...re the H3C UniServer BX720E switch module BX720E for short provides data switching functions for servers installed in the front slots of the blade enclosure and centrally provides external data ports...
Page 6: ...ade servers A switch module connects to a blade server through two internal ports configured in active backup mode which ensures high availability of internal links in the blade server chassis Specifi...
Page 7: ...to 5000 m 196 85 to 16404 20 ft Port This section describes numbering rules positions quantity and other information about the ports of the switch module Port numbering rules Ports of the switch modul...
Page 8: ...ly used by technical support engineers to upgrade the AMC firmware 2 SYS serial port Console port RJ 45 1 Serial port used for local management debugging and maintenance of the switch module The baud...
Page 9: ...ed on slots in pairs slots 1 and 4 2 and 5 and 3 and 6 Port numbers are XGE 1 0 33 through XGE 1 0 36 These four internal ports are interconnected to each other through the mid plane As a best practic...
Page 10: ...mote management through SOL or the firmware is being updated through the OM module Off The UID LED is not activated 2 RUN LED RUN Green Steady green off The system is faulty Flashing green 4 Hz The sy...
Page 11: ...cted the port rate is 10 Gbit s but no data is transmitted Flashing yellow The port link is connected the port rate is 10 Gbit s and data transmission is in progress Off The port link is not connected...
Page 12: ...r details see Table 5Figure 7 and Table 5Figure 8 Six switch module slots can be divided into three pairs corresponding to three switching planes Where slots 1 and 4 slots 2 and 5 and slots 3 and 6 fu...
Page 13: ...d to identify the mapping between Mezz NIC slot and switch module slot The specific positions of the Mezz NIC slots and switch module slots should be subject to the module silkscreens H3C UniServer B7...
Page 14: ...NIC 4 are connected to switch modules in slot 1 and slot 4 Mezz NIC 2 and Mezz NIC 5 are connected to switch modules in slot 2 and slot 5 Mezz NIC 3 and Mezz NIC 6 are connected to switch modules in...
Page 15: ...ables Table 7 Optical modules cables compatible with the switch module Model Type Center wavelength Transmission distance Description SFP GE T CM SFP 100 m 328 08 ft GE electrical module SFP GE T SFP...
Page 16: ...QSFP 40G D AOC 10M QSFP 10 m 32 80 ft QSFP active optical cable QSFP 40G D AOC 20M CM QSFP 20 m 65 62 ft QSFP active optical cable QSFP 40G D AOC 20M QSFP 20 m 65 62 ft QSFP active optical cable QSFP...
Page 17: ...FP SFP modules may change over time If you need accurate information about module types consult H3C marketing or technical support personnel When installing optical modules and cables wear ESD wrist s...
Page 18: ...tion tools The following tools or devices may be required when you install use and maintain the equipment Table 9 Required tools Image Name Description Diagonal pliers Used to clip insulating sleeves...
Page 19: ...up data of the switch module Before replacing a component check the slots and connectors and ensure that the pins are not damaged for example check whether pins are deformed or whether foreign objects...
Page 20: ...out the switch module to be installed from the ESD bag 4 Press the unlock button to automatically open the ejector 5 Slowly insert the switch module into the blade enclosure horizontally with UP facin...
Page 21: ...on green For specific positions of LEDs see LEDs Method 1 The switch module is energized by the blade enclosure If the switch module is pre installed it is automatically energized when the blade enclo...
Page 22: ...Figure 9 Logging in to the web UI of the OM module 3 As shown in Figure 10 perform the following steps to power on the switch module a Click Switch Module b Select a target switch module c Click Powe...
Page 23: ...ta in the table is for illustration only The actual data during on site operations shall prevail 2 After login the OM CLI displays the login page as shown below Copyright c 2004 2019 New H3C Technolog...
Page 24: ...manual intervention Mode 2 The switch module is powered off through the OM web UI 1 Before powering off the switch module through the OM web UI obtain the data listed in Table 14 Table 14 Data Data De...
Page 25: ...OK As shown in the red frame in Figure 14 ensure that the switch module is powered off Figure 13 Powering off the switch module Figure 14 Ensuring that the switch module is powered off Mode 3 The swi...
Page 26: ...elivery The data in the table is for illustration only The actual data during on site operations shall prevail 2 After login the OM CLI displays the login page as shown below Copyright c 2004 2019 New...
Page 27: ...te operations shall prevail Login mode You can log in to the switch module in the following modes Log in to the switch module through the SYS serial port Console port of the switch module For details...
Page 28: ...r written consent no decompiling or reverse engineering shall be allowed Sysname Logging in to the SOL serial port through redirection Prerequisites The switch module has been powered on For details s...
Page 29: ...ion mode You can configure the management IP address of the switch module in the following modes Configure the management IP address of the switch module through the web UI of the OM module For detail...
Page 30: ...Position button to enable the function of configuring the management IPv4 address of the ICM module and configure the management IP address of the ICM module as shown in Figure 16 Click Apply Figure...
Page 31: ...nd save the configuration in the profile OM auto ipv4 address 192 168 200 1 mask 255 255 255 0 gateway 192 168 200 254 io 1 save enable Configure the management IP address but do not save the configur...
Page 32: ...669171 Apr 29 2019 10 50 55 startup mdb 8 rw 5705728 Apr 28 2019 14 35 55 uis cmw710 boot 1 00 10 bin 9 rw 108381184 Apr 28 2019 14 36 52 uis cmw710 system 1 00 10 bin 10 rw 7168 Apr 29 2019 14 06 09...
Page 33: ...fg Press CTRL C to abort Total Received Xferd Average Speed Time Time Time Current Dload Upload Total Spent Left Speed 100 6549 0 0 100 6549 0 270k 319k Sysname Common operations Logging in to the Web...
Page 34: ...f the OM module Logging in to the CLI of the OM module Prerequisites The blade enclosure has been energized You have obtained the login data of the OM module Procedure 1 As shown in Figure 20 connect...
Page 35: ...used to log in to the OM module User name default admin Password default Password _ The SSH access mode is enabled for the OM module by default The data marked default are configured before factory de...
Page 36: ...1 Firmware upgrade For specific procedures see the H3C UniServer B16000 Blade Server Upgrade Guide...