background image

Warranty & Technical Data

TECHNICAL DATA

Item

Material / Comments

Lid

Polycarbonate

Valve Body (DN40 and DN50/65)

CPVC

Lid Screws

304 Stainless Steel

O-ring

Silicone Lubricated Elastomer

Scale label, Product label

Polycarbonate

Pivot Pin

Hastelloy c-276

Spring

Hastelloy c-276. 316 Stainless Steel prior to Nov. 2015

DN80 and DN100 Tee and reducing bushings

PVC

Indicator Arm

ABS

Flapper DN40 and DN50/65

PPEPS

Flapper Seal DN40 and DN50/65

Viton

Lower Flapper (DN80 and DN100 only)

ABS

Interconnecting link (DN80 and DN100 only)

316 Stainless Steel

Lower Retaining Pins (DN80 and DN100 only)

316 Stainless Steel

Materials used:

Function

Models

Comments

Max working pressure

All models

3.5 Bar

Accuracy

FV-C-M-DN40 and FV-C-M-DN50/65

Average: 97.9% / 98% / 97.5%

Accuracy

FV-M-DN80 and FV-M-DN100

Average: 98.6% in straight pipe

Min / Max operating ambient temp

All models

0˚C / 60˚C

Periodic calibration

All models

None required

Design life

All models

Greater than 5 years

Operational Data:

WARRANTY

For a copy of the FlowVis warranty, please contact the factory. 

Summary of Contents for FlowVis DN100

Page 1: ...g floats or paddle wheels Combined Flow Meter and Check Valve for DN40 and DN50 65 CONCEPT As flow increases the flapper moves forward toward its fully open position The flapper s angular position is directly related to flow rate through the valve body tee A calibrated scale on the valve s lid provides a highly accurate reading of the flow rate Calibrated Scale Flow www h2flow net Tel 1 419 841 77...

Page 2: ...When selecting a physical location to install FlowVis be sure to allow accessibility to read the scale on the lid Pay particular attention to the system s direction of flow and make sure that the arrow on the lid of the FlowVis is pointing in the correct direction For the DN80 and DN100 versions the Tee will have an additional arrow on one of its bosses In the event that the FlowVis is inadvertent...

Page 3: ...hlorine Feeders damaging other equipment such as Heaters www h2flow net Tel 1 419 841 7774 www drydenaqua com Installation Tightening Lid Screws 3 TIGHTENING LID SCREWS When removing and re installing the FlowVis lid assembly it is important to adhere to the following procedure 1 Make sure that the o ring on the underside of the lid is undamaged lubricated with silicone such as Boss 820 and is in ...

Page 4: ...d near the rear of the lid 2 Indicator arm is being viewed correctly 3 Indicator arm is being viewed too far back front of the lid MAINTENANCE Although FlowVis is designed to be maintenance free periodic checks should be made to the following Condition Check for Remedy Leak around lid seal O Ring Failure Replace O Ring Leak from lid Cracks in lid Order new lid from supplier Higher flow reading tha...

Page 5: ...0 08 0 10 0 12 0 14 0 16 5 7 9 11 13 15 17 19 21 23 25 Head Loss Bar FlowRate m3 h Head Loss Bar DN50 Head Loss DN50 0 000 0 005 0 010 0 015 0 020 0 025 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 Head Loss Bar FlowRate m3 h FlowVis HeadLoss Bar DN80 Head Loss DN80 0 004 0 006 0 008 0 010 0 012 0 014 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 Head Loss Bar FlowRate m3 h FlowVis H...

Page 6: ...DN40 and DN50 65 Viton Lower Flapper DN80 and DN100 only ABS Interconnecting link DN80 and DN100 only 316 Stainless Steel Lower Retaining Pins DN80 and DN100 only 316 Stainless Steel Materials used Function Models Comments Max working pressure All models 3 5 Bar Accuracy FV C M DN40 and FV C M DN50 65 Average 97 9 98 97 5 Accuracy FV M DN80 and FV M DN100 Average 98 6 in straight pipe Min Max oper...

Reviews: