www.myhtec.com
17
CAUTION
Risk of fire due to electrical overload
Any operation beyond the electrical specifications will lead to
excessive overheating of the electroly
z
er. This may cause a fire.
Never operate the electroly
z
er beyond the electrical specifications
stated in the technical data.
CAUTION
Risk of damage due to electrical overload
Any operation beyond the electrical specifications will lead to
irreparable damage to the electroly
z
er.
Never operate the electroly
z
er beyond the electrical specifications
stated in the technical data.
CAUTION
Risk of damage due to voltage
Applying voltage to a fuel cell or a solar module leads to irreparable
damage to the components.
Do not apply voltage to fuel cells and solar modules.
CAUTION
Risk of damage due to insufficient distance to lamps
The solar module may become excessively hot or sustain irreparable
damage if it is too close to the lamp.
Observe the minimum distance defined by the manufacturer when
operating solar modules with lamps.
CAUTION
Risk of damage due to improper handling
Operating the electroly
z
er using water with an electrical conductivity
of
σ
≥
2 µS/cm will cause irreparable damage to the electroly
z
er.
Only fill the electroly
z
er using distilled water with an electrical
conductivity of
σ
< 2 µS/cm.