14
www.myhtec.com
5. Place the acrylic housing on the screws.
6. Place the remaining washers and nuts on the
screws, and screw the nuts finger-tight at first.
7. Tighten the nuts alternately a little at a time
(max. two and one-half turns) until a gap of
4mm is left between the acrylic plates.
Caution!
Caution!
Overtightening may damage the electrodes. We
recommend that the distance be checked by
means of a caliper. Should a caliper or similar
instrument not be available, tighten the nuts
twice, approximately half a turn each time.
8. Screw the fittings into the four holes in the
housing plates.
Assembly
Technical Data
H x W x D:
Weight:
H
2
/ O
2
Power:
H
2
/ Air Power
(with O
2
Plate)
:
H
2
/ Air Power
(with Air Plate)
:
Permissible Voltage:
Electrode Area:
Permitted operating pressure:
100 x 80 x 90 mm
0.2 kg
1 W @ 1.5 A
880 mW @ 1.5 A
1.2 W @ 2A
0.4 - 1 VDC
16 cm
2