25
TITAN 400 DC
EN
INSTALLATION
• Put the machine on the floor (maximum incline of 10°.)
• Provide an adequate area to ventilate the machine and access the controls.
• Do not use in an area with conductive metal dust.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
• The equipment protection is rated IP23 meaning that :
- sensitive parts of the equipment are protected from objects with a diam >12.5 mm and,
- it is protected again rainfall with a 60° vertical incline.
The equipment can be used outside in accordance with the IP23 protection certification.
Power cables, extension leads and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not accept any liability in relation to damages caused to objects or harm caused to persons as the result
of incorrect and/or dangerous use of the machine.
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person. A yearly maintenance is recommended.
• Ensure the machine is unplugged from the mains, and then wait 2 minutes before carrying out maintenance work. High Voltage
and Currents inside the machine.
• Remove regularly the casing and any excess of dust. Take this opportunity to have the electrical connections checked by a qualified person, with
an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person to prevent danger.
• Ensure the vents of the device are not blocked to allow adequate air circulation.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the installation of the welding equipment. During the installation, the
operator must ensure that the machine is disconnected from the mains. Connecting generators in serial or in parallel is forbidden.
EQUIPMENT DESCRIPTION (FIG-1)
The TITAN 400 DC provides Inverter welding current designed for electrode welding (MMA & TIG) in direct current (DC).
The MMA process allows to weld all types of electrodes : rutile, basic, stainless and cellulosic.
TIG welding requires gas shield protection of pure gas (Argon).
This material can be connected to a remote control (ref. 045675), a foot pedal (ref. 045682) or an automated system (CONNECT-5).
1-
Keypad
8-
Power supply cable
2-
Torch button connector
9-
Remote controller connector
3-
- polarity plug
10-
Gas bottle connector
4-
Torch gas connector
11-
USB connector for updates
5-
Wire feeder connector or MMI remote interface
12- Handles
6-
Positive polarity plug
13-
Lifting eyes
7-
ON / OFF switch
14-
Filter (option)
INTERFACE (MMI) (FIG-2)
1-
Welding cycle (8 settings available)
6-
Sub-processes
2-
Display
7-
Button to access JOB menu
3-
Gas purge
8-
Lock/unlock button
4-
Welding processes
9-
Special mode : E.TIG
5-
Trigger mode (button)
10-
Navigation and validation scrollwheel
ACCESSORIES AND OPTIONS
Remote controllers
Trolley
10 m
3
Cooling unit
WCU1KW_C
Torches abitig
liquids - 450 W - 8 m
Pedal RC-FA1
4 m
Manual RC-HA1
8 m
Filter
037328
013537
Torch with double button :
037366
Torch with trigger : 037359
045682
045675
046580