8
Release: the important coil inertia can drive the wire rolling after end welding.
Open the gas. The machine is ready to operate.
4-8)Commissioning of the cooling liquid group
( GENEGYS 515 WSF)
•
Never operates the cooling group without filling the cooling liquid tank before the use of the machine.
•
Use the cooling liquid -25°C.
•
Fill the tank until the maximum level
For first use,
the cooling circuit must be bleeded from the water. To do this operation, you have
to connect the blue connection of the contact batch (5 or 10 meters) on the blue connection of the MIG
generator. Inject compressed air in the blue pipe of the contact batch to drive out the air bubble
contained in the pump circuit.
•
The pump can be used.
•
Connect the blue and red connection of the contact batch to the generator and the wire feeder.
•
Control that the water circulation works correctly.
•
Check the cooling liquid level before each use of the unit and complete the liquid if necessary.