12
BATIUM 7/12 • 7/24 • 15/12 • 15/24
EN
Translation of the original instructions
GENERAL DESCRIPTION
The Batium range is designed to charge all common batteries including lead-acid , electrolyte or gel batteries.
Reference
7 / 12
7 / 24
15 / 12
15 / 24
Voltage
6 V
12 V
6 V
12 V
24 V
6 V
12 V
6 V
12 V
24 V
Battery capacity
From 15 Ah to 130 Ah
From 35 Ah to 225 Ah
CONNECTIONS AND GENERAL OPERATIONS
Ensure that the correct sequences are followed.
Precaution: Check the electrolyte level for open batteries. Fill it up if necessary, before starting the charge.
1. Connect the clamps : Red clamp to the battery's (+) and black clamp to the battery's (-).
2. Connect the charger to the mains on a 230 V socket. An indicator A (interface diagram p.5) and B switches on that
matches the latest saved data.
3. Select the battery voltage (6, 12, 24 V) according to the recommendations features on the
battery or according to the battery coupling (series or parallel cf p.5).
Risk of explosion or acid projections if the wrong voltage is selec-
ted (24V for a 12V battery).
To confirm the selection,
do not press any button
for 5 seconds.
4. Select the battery capacity. The Batium automatically determines the charging current.
5. The charge starts automatically. The display indicates the battery's state of charge. (indicators
1 and 2 )
Voyant allumé
État
Step 1 :
Voltage rises
Permanent
Step 2 :
Voltage regulation (duration : 2h).
Flashing
Step 3 :
Charge ends (Floating charge).
Green
In the event of a power cut, the BATIUM saves the state of charge (except in « SOS Recovery » mode), and resumes the
charge using the latest settings.
6. When the battery is charged, disconnect the power supply
7. Disconnect the clamps or the battery connectors.
FORCED CHARGE
If the battery is deeply discharged (very low voltage <2 V), the charge doesnt not start automatically. The charge indicator
1
does
not switch on. The battery voltage indicators
A
, and capacity indicator
B
are switched on. In this situation, select the voltage and
the charging current, then press the battery voltage button
3
during 5 seconds to start a "forced charge". The indicator
1
switches
on once the buttton is released. If no indicator switches on, your battery cannot be recovered (<0.5 V (± 0.3)).
« SOS RECOVERY » (BATIUM 15/12 AND 15/24)
When connecting the battery, the SOS Recovery indicator
6
flashes to signal that the battery suffered a deep discharge over a
long period, with a start in sulfation.
The « SOS Recovery » mode uses a specific curve to repair the battery over a 24 to 48 hours cycle.
To activate this feature, follow these steps :
1.
Disconnect the battery from the vehicle. (OVERVOLTAGE DANGER)
2. Connect the Batium to the battery.
3. Connect the Batium to the mains.
4. Choose the charging voltage.
5.
Activate « Sos Recovery » by pressing the button
4
during 5 seconds, until the indicator
6
switches on (the indicators
B
are switched
off).
6.
The indicator
1
switches on and blinks when the "Sos Recovery" stops and the normal charge resumes.
7. The green indicator
2
indicated the charge is over.