24
NEOCUT 105
EN
Cutting of perforated metal sheets
Use this mode to perform cutting work on perforated metal sheets that require repetitive cutting stops / restarts.
This is a cutting mode where the arc recharges itself as long as the trigger is held down. This mode is more comfortable to
use, as it avoids constant pull and release of the trigger.
Marking out
This mode, compatible with all cutting consumables, operates at low current and allows surface marking of sheet metal.
Particularly useful for automated cutting to record for example references, bundle numbers... this mode is also accessible with
a manual torch.
FIRST START UP
At first startup, the machine will ask you to configure the following parameters:
1
2
3
(EN) ENGLISH
(FR) FRANCAIS
(DE) DEUTSCH
(IT) ITALIANO
(ES) ESPANOL
(NL) NEDERLANDS
(RU) RUSSKIY
m. /bar
ft./psi
6.0m/20ft
7.6m/25ft
12.0m/40ft
15.2m/50ft
Language
Units (m./bar or ft./psi)
Torch length assembled on the product
Rotating the scroll wheel moves the cursor in front of the desired selection, pressing the scroll
wheel validates the selection.
Note: In the event of an input error, these parameters can be changed (see Setup menu).
Important setting for the correct operation
of the product. This data is used by the power
source to calculate and apply the optimum
operating pressure.
HMI NAVIGATION
SCROLL WHEEL USE
Turning the scroll wheel allows
- an adjustment of a digital parameter (current, pressure)
- moving the cursor to make a selection
Pressing the scroll wheel
- allows to confirm a selection (pointed by the cursor)
- access the toolbar from the main screen or from the pressure setting screen
MAIN SCREEN
(CURRENT SETTING):
5.2 bar
6.0m
105
A
1
2
3
4
This screen is displayed as soon as the machine is started:
1- Operating mode
2- Current pressure*
3- Selected torch length
4- Current
The current setting is made directly from this screen.
*An arrow pointing up or down may appear to the right of the pressure when the pressure has been incorrectly altered by the user, the arrow disappears when the set
pressure is optimal or the pressure setting is set in «auto» mode.
TOOLBAR
(ACCESS VIA SCROLL WHEEL)
105A
5.2 bar
Setup
1
2
3
4
1- Access to the mode selection screen
2- Access to the main screen (current setting)
3- Accessing the pressure adjustment screen
4- Access to the Setup menu
Summary of Contents for 063044
Page 2: ...2 NEOCUT 105 1 2 3 4 9 10 11 6 5 7 8 FIG 1...
Page 62: ...62 NEOCUT 105 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Page 63: ...63 NEOCUT 105 RU 11 2 A CEI 61000 3 11 CEI 61000 3 12 EMF EMF...
Page 64: ...64 NEOCUT 105 RU b c d e f g h 10 CISPR 11 2009 a b c d e f...
Page 72: ...72 NEOCUT 105 RU 1 2 3 5 0 bar 105A 105A 7 3 bar 152V 1 4 5 6 2 3 1 2 3 4 5 6 1 90 2 3 1 30...
Page 73: ...73 NEOCUT 105 RU 2 30 90 3 4 1 45 2 2 45 3...
Page 76: ...76 NEOCUT 105 RU 2...