MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person. A yearly maintenance is recommended.
• Ensure the machine is unplugged from the mains, and then wait 2 minutes before carrying out maintenance work. Inside,
voltages and currents are high and dangerous.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person to prevent danger.
• Ensure the vents of the device are not blocked to allow adequate air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
Air filter maintenance :
Purge of the filter tank :
• Unplug the air supply.
• Loosen the valve in the lower part of the filter tank by turning it anticlockwise.
• Push the tap upwards to drain the water from the tank.
• Tighten the valve at the bottom of the filter tank by turning it clockwise.
Removing the filter element :
• Disconnect the air supply.
• Take hold of the tank and unscrew it from the body by turning it anticlockwise.
• The filter element (white) can be blown out or replaced depending on its condition.
Reassembling the filter element :
• Put the filter element back in the tank, check the presence of the O-ring in the upper part.
• Screw the tank back onto the body by turning it clockwise.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the installation of the welding equipment. During the installation, the
operator must ensure that the machine is disconnected from the mains.
MACHINE SUPPLIED WITH
NEOCUT 105
Ref. 063044
Ref. 063112
4 m - 16 mm²
Pneumatic fittings
8 mm + 10 mm
8 mm + 10 mm
6 m
-
Starting kit
-
Accessories supplied with the generator are designed to be used on this machine only.
DESCRIPTION
NEOCUT 105 is a three-phase Plasma cutting & gouging machine, it will allow:
- Cutting on all metal types
- Gouging on all metal types
- Marking on all metal types
These 3 processes require the use of appropriate consumables as well as compressed air or nitrogen.
EQUIPMENT DESCRIPTION (FIG. 1 - PAGE 2)
1-
Display screen
7-
Transport handles.
2-
Adjustment knob
8-
Replacement for pneumatic connector
3-
Earth clamp connection socket
9-
Power supply cable
4-
Plasma torch connector
10-
On/off switch
5-
Installation door for analog CNC 1 connector
(option, ref. 039988)
11-
Filter
6-
Installation door for digital CNC 2 connector
(option, ref. 064737)
Summary of Contents for 063044
Page 2: ...2 NEOCUT 105 1 2 3 4 9 10 11 6 5 7 8 FIG 1...
Page 62: ...62 NEOCUT 105 RU 10 40 C 14 104 F 20 55 C 4 131 F 50 40 C 104 F 90 20 C 68 F 1000 3280 10...
Page 63: ...63 NEOCUT 105 RU 11 2 A CEI 61000 3 11 CEI 61000 3 12 EMF EMF...
Page 64: ...64 NEOCUT 105 RU b c d e f g h 10 CISPR 11 2009 a b c d e f...
Page 72: ...72 NEOCUT 105 RU 1 2 3 5 0 bar 105A 105A 7 3 bar 152V 1 4 5 6 2 3 1 2 3 4 5 6 1 90 2 3 1 30...
Page 73: ...73 NEOCUT 105 RU 2 30 90 3 4 1 45 2 2 45 3...
Page 76: ...76 NEOCUT 105 RU 2...