9
GYSFLASH 1.12 LITHIUM
EN
TROUBLESHOOTING
Troubleshooting
Causes
Solutions
1 The indicator
blinks rapidly.
• Polarity reversal
• Battery voltage is too high
• Check that the clamps are properly connected.
• Check that it is a 12V battery.
2 The indicator
blinks slowly.
Battery is faulty or has a very low
voltage.
Change the battery.
3 The indicator
is on.
• Charge failure, battery non recove-
rable.
• Thermal protection.
• Change the battery and restart a charge.
• Ambient temperature is too high (>50°C), cool
the room and let the charger cool down.
4 The indicator
blinks.
Charger in sleep mode.
Connect a battery to the charger to exit sleep
mode.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported