10
GYSFLASH 6.24 PL
EN
• Load curve Lead:
The GYSflash 6.24 PL uses a 7-step lead charging curve that guarantees the optimal performance of your lead battery.
U
I
1
2
3
4
5
6
7
Analysis
Recovery
Test
Desulfation
Charge
Absorption
Load retention
CHARGE
OK
Le
d
Max 12h
<1s
Max 8h
<1s
Max 20h
Max 8h
No limit
Step
1
: Analysis
Analysis of the battery condition (charge level,polarity rever-
sal, incorrect battery connected...)
Step
5
: Charge
(6 A)
Maximum current fast charge to reach an 80% charge level.
Step
2
: Recovery
(3 A)
Recovering damaged elements due to a prolonged deep
discharge.
Step
6
: Absorption
(29.2 V)
Constant voltage charge to reach 100% charge level.
Step
3
: Test
Sulfated battery test
Step
7
: Load retention
(27.2 V)
Maintain the battery charge level at its maximum.
Step
4
: Desulfation
(31.6 V)
Battery desulfation algorithm.
• Lithium charging curve :
The GYSflash 6.24 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your lithium
battery.
U
I
1
2
3
4
5
6
7
Analysis
Recovery
Charging
Absorption
Complement
Equalization /
balancing
Charge retention
< 1s
Max 5 min
Max 25 h
Max 20 h
3 min
Max 10 h
Max 2 h
No limit
(maintenance every 10 days)
CHARGE
OK
Le
d
8
Test
Equalizing Battery System
Step
1
: Analysis
Analyses the state of the battery (charge level, polarity inversion,
wrong battery…)
Step
5
: Test
Charge hold test.
Step
2
: Recovery
(0.5 A)
Recovery algorithm following a deep discharge.
Step
6
: Complement
Reduce current charge to reach 100% charge level.