• Load curve Lead:
The GYSFLASH 15.24 PL-E incorporates an advanced 6 (or 7) step charging curve that guarantees the optimal perfor
-
mance of your battery. This automatic charging curve is adapted to all types of lead-acid batteries (liquid and AGM)
in order to guarantee an optimal charge level of your battery. This curve is perfectly compatible with the presence of
consumers on the battery.
1
2
3
4
5
6
7
Analysis
Recovery
Desulfation
Charge
Absorption
Floating
Traction
if the option is activated
Max 12h
<1s
Max 8h
Max 20h
Max 8h
1h - 4h
No limit
Step
1
: Analysis
Analysis of the battery condition (charge level, inversion,
polarity, wrong battery connected, etc).
Step
5
: Absorption
(14.6 V)
Charge under constant voltage
(liquid : 14.4 V, AGM : 14.8 V)
to bring the charge level to 100%
Step
2
: Recovery
(6 A)
Recovering damaged elements after deep and prolonged
discharge.
Step
6
: Traction
(31 V)
If the traction option has been selected, the charger will then
inject an additional current to create gas to mix the electrolyte and
recondition the battery cells. During this phase, the battery may
lose a bit of water.
Step
3
: Desulfation
(15.8 V)
Battery desulfation algorithm.
Step
7
: Floating
(13.6 V)
Maintains the battery charge level at its maximum level
(liquid : 13.5 V, AGM : 13.5 V)
.
Step
4
: Charge
(18 A)
Fast charging at maximum current up to 80% of the charge
level
(liquid : 14.4 V, AGM : 14.8 V)
.
• Lithium charging curve :
The GYSFLASH 15.24 PL-E uses an advanced 6-step lithium charging curve that ensures optimal battery performance. This automatic
charging curve is adapted to all types of Lithium batteries to ensure an optimal charge level of your battery. This curve is perfectly
compatible with the presence of consumers on the battery.
12
GYSFLASH 15.24 PL-E
EN
Translation of the original instructions