background image

8

CT 160 / 210

EN

Translation of the original instructions

DESCRIPTION OF THE CHARGER (FIG I, PAGE 36)

The chargers CT 160 and CT 210 are designed to charge lead acid batteries with liquid electrolyte, nominal voltage 

from 12V, and with capacity according to the table II, page 41.

1 – Ammeter

5 – Fuse

2 – Battery voltage selector

6 – clamps

3 – Battery capacity selector

7 – handle (CT 210 only)

4 – Main switch

8 – Power supply (CT160 : fixed / CT210 : removable)

CHARGER MODE

Preliminary precautions

• 

For indoor use, with good ventilation. Protect the charger from rain and moisture.

• 

Remove the battery caps if there is, and check the level of liquid. If it is not correct, filled up with distilled water. 

Clean well the battery terminals.

• 

Check if the battery capacity and voltage are compatible with your charger. 

Do not charge the battery when it 

is connected on the vehicle.

Connection and disconnection

•  Disconnect from the battery all electronic system during the charge (do not charge the battery when it is connected 

on the car).

•  Plug in your charger to 230 V 50/60 Hz mains supply.

• 

Connect the clamps (+ red, - black) to + and - battery terminals, making sure you get a good electric contact, 

respecting the following order:

 

◦ Connect first the battery terminal not connected to the chassis of the vehicle.

 

Then connect the other connection to the chassis remote from the battery and any fuel line.

• 

Choose the charge voltage (12 / 24V) and the charge speed (normal or boost). The « Boost » function allows 

charging a battery quickly.

Control and end of the charge process

• 

These are traditional chargers; the charge process must be stopped manually.

•  The ammeter is a charge indicator. When the current drops down to 0, the battery charge is ending. You can stop 

the charge process. In normal mode, it takes about 10 hrs to fully charge a battery. If the ammeter is not at the 

minimum after this period, check the charge mode and voltage or have the battery checked by a professional.

•  Do not let the charger connected more than 24 Hours on a battery.

• 

After charging, disconnect the battery charger from main supply. Then remove the chassis connection and the 

battery connection, in this order.

PROTECTIONS 

Your product has been developed with a maximum of protections:

•  The clamps of the battery are isolated.

• 

The polarity reversal will not cause danger. The protection is insured by an automotive fuse, which must be changed 

in case of polarity error. Respect the rating of the fuse, which is indicated on the charger.

• 

This device is protected by an internal fuse to avoid any risk in case of damage to the charger.

•  (CT160 : 1,6A – CT210 : 2A)

•  Thermal protection: the transformer of the product is protected by a thermal switch. If the charger is used  

intensively, it may switch in thermal protection mode (cooling time about 15min), and then resume the charge.

Summary of Contents for 024106

Page 1: ...ad acid or calcium batteries for small cars vans and agricultural vehicles Copper wound transformer Clamp cables 1 5m Power supply cable 1 3m Thermal protection of the transformer Protection against p...

Page 2: ...d acid or calcium batteries for small cars vans and agricultural vehicles Copper wound transformer Clamp cables 1 5m Power supply cable 1 3m Thermal protection of the transformer Protection against po...

Page 3: ...C51319_V11_10 12 2020 CT 160 www gys fr CT 210...

Page 4: ...and by persons with reduced physical sensory or mental capabilities or lack of ex perience and knowledge provided that they are under supervision or have been told how to use the device safely and ar...

Page 5: ...service agent or an equally qualified person Service should be performed by a qualified person Warning Always remove the power plug from the wall socket before carrying out any work on the device Ifth...

Page 6: ...r connection to the chassis remote from the battery and any fuel line Choose the charge voltage 12 24V and the charge speed normal or boost The Boost function allows charging a battery quickly Control...

Page 7: ...tage Following intensive use your device has entered thermal protection mode Wait 1 4h so the device can cool down The anmeter s pin goes above the maximum marking while the device is set to minimum i...

Page 8: ...y Voltage Netzspannung Tensi n de la red Netspanning Tensione d ali mentazione 230V 50 60Hz 230V 50 60Hz Puissance nominale max Max nominal power Max Leistung Potencia nominal m x Maxi maal nominaal v...

Page 9: ...CHEMA SCEMA ELETTRICO CT 160 CT 210 COMPOSANTS COMPONENTS KOMPONENTEN COMPONENTES ONDERDE LEN COMPONENTI CT160 CT210 Fusible 15A x10 Fuse 15A x10 Schmelzsicherung 15A x10 Fusible 15A x10 15A x10 Zeker...

Page 10: ...tizando a un sistema global de separaci n recogida selectiva y reciclado de los deshechos de embalajes dom sticos Questo materiale soggetto alla raccolta differenziata Non deve essere smaltito con i r...

Page 11: ...1 C51335_V11_20 10 2020 GYS CT 160 CT 210...

Page 12: ...CT 160 210 BG 2 8 50 C...

Page 13: ...CT 160 210 BG 3 EAC C CMIM...

Page 14: ...CT 160 210 BG 4 I CT 160 CT 210 12V II 1 5 2 6 3 7 CT 210 4 8 CT160 CT210 230 V 50 60 Hz 12 24V Boost 0 10 24 CT160 1 6A CT210 2A 15...

Page 15: ...CT 160 210 BG 5 2 5V 12 24V 12 24V 1 4 1 4 12 24V 12 24V 12V 24V 12V 2...

Page 16: ...0 Ah 24V 20 Ah 100 Ah TECHNICAL FEATURES CT 160 CT 210 Supply Voltage 230V 50 60Hz 230V 50 60Hz Max nominal power 190W 260W Charge voltage 12V 24V 12V 24V Charge current 9A 5A 12A 6A Charging curve Ty...

Page 17: ...CT 160 210 CIRCUIT DIAGRAM SCHALTPLAN DIAGRAMA ELECTRICO ELEKTRISCHE SCHEMA SCEMA ELETTRICO CT 160 CT 210...

Page 18: ...negra 40A 40A Zwarte klem 40A Morsetto nero 40A 72022 Transformer Transformator Transformador Transformator Trasformatore 53187 53188 Power supply cable Netzkabel Cable de red el ctrica Elektrische n...

Reviews: