4
2. Installation & Adjustment
2.1 Parameters
Note: The above parameters are subject to change with the improvement of machines.
PLASMA
ARC45
2.2 Installation
1. Unpacking
1. Use the packing lists to identify and account for each item.
2. Inspect each item for possible shipping damage. If damage is evident, contact GWS and / or shipping company before
proceeding with the installation.
2. Input Power Connections
Note: Check your power source for correct voltage before plugging in or connecting the unit.
3. Air/Gas Connections
1. Connecting Air/Gas Supply to Unit
- Connect the gas line to the inlet port of the gas filter on the rear panel.
2. Check Air Quality
- To test the quality of the air, press on the function button briefly - check if there is any oil or moisture in the air.
Power Supply Voltage (V)
Frequency (Hz)
Rated input power (KW)
Pilot Current (A)
No Load Voltage (V)
50/60Hz
PLASMA
ARC
45A
Machine
Max Cutting Thickness (mm)
Net Weight (Kg)
Dimensions (mm)
Protection Class
Cooling
Insulation Class
1-230±10%
7.0
33.8
230
CUT/Grid
10-45
20
0.99
60%40A 100%32A
12.6
480x175x310
IP23
F
FAN
Rated Input Current (A)
Power Factor
Duty Cycle (40°C 10min)
Cutting Current Range (A)
Gouge
20
Quality
Cutting
Thickness
(mm)
Carbon Steel
Stainless Steel
Aluminium
Copper
25
≤
20
≤
16
≤
12
≤
Standard
EN60974-1