GW Security GWSW1602G User Manual Download Page 8

 

11

12

3 2 2 

. .  Confirm the Network Connection by Ping Command

Operation Steps as below:

 

(1) 

menu, select [Run], pop out the dialog. 

Click

 <

Start

>

 button

 

to

 

enter

 [

Start] 

(2) 

<

confirm> button. If there is equipment 

response shown in the pop out dialog, that 

means network connection succeed, 

otherwise please check if the network 

connection is correct.

Input

 "

ping

 

192

.

168

.

1

.

200

", 

click

 

 

 

3 2 3 

. . Cancel the Proxy Server

If

 

this

 

management PC uses  proxy server to visit the Internet, then you must prohibit

 

the

 

proxy

 

service

following

 

is

 

the

 

operation

:

 

(

1

In

 

browser, select [ tool/Internet 

option] enter [Internet option] window.

3.3 Operating Guidance of Web

 

3 3 1 

. .

Start and Login

 

T h i s  p r o d u c t  w e b  d e f a u l t  I P  a d d r e s s :  1 9 2 . 1 6 8 . 1 . 2 0 0 ,  s u b n e t  m a s k : 

255.255.255.0,  administrator  account

admin,  password

admin.  After 

installing  the  equipment  correctly  and  setting  up  the  computer,  open  the 

browser,  input  the  injector  default  address  in  the  browser  address  bar: 

, then press the Enter key, the user login page will show in 

front of you as follows:    

http://192.168.1.200

The browser version recommended

:

IE7 and later, Firefox browser, Chrome, 360 

browser (IE7 and later).

(2) Select  connection tabs in [Internet 

option] window, and click [LAN Setting] 

button.

” 

 

(3) Make sure the “Use proxy server for LAN”option is not selected. If selected, please 

cancel it and click <yes> button.

 

Summary of Contents for GWSW1602G

Page 1: ...16 24 Ports PoE switch User Manual...

Page 2: ...1 1 2 Board Diagram 1 3 Specification 2 1 4 Product Feature 3 2 Installation 4 2 1 Shipping List 4 2 2 Installation Precautions 4 2 3 Installation Way 6 2 3 1 Rack Installation 6 2 3 2 Workbench Insta...

Page 3: ...oE Web Management Port PoE Output LED Reset PoE Output Percentage LED PoE Output Ports Reset PoE Web Management Port PoE Output LED Uplink Gigabit Ports PoE Output Percentage LED 24 Ports PoE switch A...

Page 4: ...Terminal 1 Grounding Terminal PoE Power Power Input Mains on load 100 240VAC 50 60Hz PoE Power Supply End span 1 2 3 6 IEEE802 3 af at PoE Max Power Output 250W 370W 340W if 110V AC input Single Port...

Page 5: ...h may be affected by external interference outside the system through the ways of radiation and conduction Please pay attention to the followings AC power supply is TN system so it is necessary to use...

Page 6: ...ort switch when install the switch to the rack 2 3 2 Workbench Installation You can put this product on clean stable grounded workbench The installation procedure is as below 1 Put the device upside d...

Page 7: ...urself Operation steps take Windows XP as sample 1 Click start to enter the start menu select control panel Double click network connection icon double click the local connection icon pop out local co...

Page 8: ...rnet option enter Internet option window 3 3 Operating Guidance of Web 3 3 1 Start and Login This product web default IP address 192 168 1 200 subnet mask 255 255 255 0 administrator account admin pas...

Page 9: ...and wait for 10 seconds till product IP address is successfully changed 13 14 After inputting the correct user name and password click Login and the browser will show the product Web management page a...

Page 10: ...at the computer IP address and the product IP address must be in the same network segment and the settings of subnet mask and gateway must be correct 2 When changing product IP address please ensure t...

Page 11: ...power to be contributed decreases and the number of PoE equipments to be connected decreases on the contrary the more the number of PoE equipments to be connected the higher risk of system overload 4...

Page 12: ...port and popup dialog box Take port 1 as an example press OK popup setup is successful When setting succeeds corresponding button becomes 1 Actual output total actual output power 2 Surplus the power...

Page 13: ...meters press OK button of the corresponding port then popup setting success when operation finishes Setting all the port parameters press port control and status actual output power W button then popu...