GW Security GWSW1602G User Manual Download Page 11

(1) Power input: The total power provided by the product  for PoE supply, i.e.  the 
power provided by built-in 54V power, has been set up when it leaves the factory, 
please do not modify it. If users modified the  power supply,  please correct this 
setting. If the setting value is larger than the  actual power of the built-in power 
supply, there will be a damage of built-in power. If the setting value is smaller than 
the actual power of built-in power supply, built-in power supply could not be fully 
allocated out. 

(2) Allowing maximum overload: built-in power allows overload value setting range 
is 0%-10%, default is 5%.  If actual power is too large that cause built-in power 
overload exceeding setting value, the system will turn off power supply of low 
priority ports. For example:when input power is 360w, maximum overload is 5%. 
when actual output power exceeds 360*(1+5%)=378w , the system overloads.

(3) Power Reservation: power reservation could not be contributed, but be used for 
PoE equipment consumption due to load changes. Default power reservation is 
15% of total power. The higher the value, the slower the risk of system overload, the 
power to be contributed decreases,  and the number of PoE equipments to be 
connected decreases; on the contrary , the more the  number of  PoE equipments to 
be connected, the higher risk of system overload.  

(4) Operation instructions: after setting the value, press <OK> button. Setting 
succeeds  when the following  window pops out.

3.3.2.9 Power Status

 

Power status page diagram 

The input power, allowing maximum overload and reserved power have 

been set up before the product leaves the factory. User is allowed to modif 

it, prudently.

3.3.2.8 PoE Setting

 

Diagram of PoE setting page

3 3 2 5 Restore IP Address and Login Password

. . .

 

Start the product, unplug the network cable  of console port, then press init 

key(3

5 seconds), till the RJ45 LED light of console port flash once, the IP 

address and login password  will be restored to  the initial setting.  

 

3 3 2 6 Equipment Information

. . .

Click menu bar [equipment information] on Web page , then three product 

information of [IP address], [MAC address] and [software version] will be popped 

out for user checking. After  review, click <Exit> to log out checking status. 

  

Equipment information diagram

3 3 2 7 Exit

. . .

Click

 

main

 

menu

 [

Exit

to

 

return

 

to

 

login

 

page

.

  

Diagram of restore IP address, login password

 

17

18

Instruction

PoE Output Ports

PoE

 

Web 

Management  

Port

PoE

 

Output 

LED

Reset

PoE Output 
Percentage 

LED

Summary of Contents for GWSW1602G

Page 1: ...16 24 Ports PoE switch User Manual...

Page 2: ...1 1 2 Board Diagram 1 3 Specification 2 1 4 Product Feature 3 2 Installation 4 2 1 Shipping List 4 2 2 Installation Precautions 4 2 3 Installation Way 6 2 3 1 Rack Installation 6 2 3 2 Workbench Insta...

Page 3: ...oE Web Management Port PoE Output LED Reset PoE Output Percentage LED PoE Output Ports Reset PoE Web Management Port PoE Output LED Uplink Gigabit Ports PoE Output Percentage LED 24 Ports PoE switch A...

Page 4: ...Terminal 1 Grounding Terminal PoE Power Power Input Mains on load 100 240VAC 50 60Hz PoE Power Supply End span 1 2 3 6 IEEE802 3 af at PoE Max Power Output 250W 370W 340W if 110V AC input Single Port...

Page 5: ...h may be affected by external interference outside the system through the ways of radiation and conduction Please pay attention to the followings AC power supply is TN system so it is necessary to use...

Page 6: ...ort switch when install the switch to the rack 2 3 2 Workbench Installation You can put this product on clean stable grounded workbench The installation procedure is as below 1 Put the device upside d...

Page 7: ...urself Operation steps take Windows XP as sample 1 Click start to enter the start menu select control panel Double click network connection icon double click the local connection icon pop out local co...

Page 8: ...rnet option enter Internet option window 3 3 Operating Guidance of Web 3 3 1 Start and Login This product web default IP address 192 168 1 200 subnet mask 255 255 255 0 administrator account admin pas...

Page 9: ...and wait for 10 seconds till product IP address is successfully changed 13 14 After inputting the correct user name and password click Login and the browser will show the product Web management page a...

Page 10: ...at the computer IP address and the product IP address must be in the same network segment and the settings of subnet mask and gateway must be correct 2 When changing product IP address please ensure t...

Page 11: ...power to be contributed decreases and the number of PoE equipments to be connected decreases on the contrary the more the number of PoE equipments to be connected the higher risk of system overload 4...

Page 12: ...port and popup dialog box Take port 1 as an example press OK popup setup is successful When setting succeeds corresponding button becomes 1 Actual output total actual output power 2 Surplus the power...

Page 13: ...meters press OK button of the corresponding port then popup setting success when operation finishes Setting all the port parameters press port control and status actual output power W button then popu...

Reviews: