AC VOLTAGE INPUT
100~240VAC 50-60Hz
CONNECT END-OF-LINE RESISTOR (120 OHM)
TO DMX OUTPUT (DATA+(WHITE) AND DATA- (BLUE)) OF LAST LUMINAIRE
ISOLATE DMX COMMON OUTPUT
ORANGE = DATA+
WHITE/ORANGE = DATA-
WHITE/GREEN = COMMON
GREEN = OPEN
TO LAST LUMINAIRE ON DATA LINE
WATERPROOF JUNCTION BOXES (BY OTHERS)
DMX DATA INPUT
2xUTP CAT5 DATA CABLE
OUTDOOR RATED
(BY OTHERS)
WHITE, BLUE = NEUTRAL
BLACK, BROWN = LIVE
GREEN(/YELLOW) = GROUND
IG-FL 26.10.10
5
Wiring Diagram - DMX Version
WARNING
Ensure that power supply is off before installing or wiring FL LED Luminaire.
Do not attempt to install or use FL LED Luminaire until you read and understand this instruction manual and
safety labels.
FL Luminaires must be installed by a qualified professional in accordance with NEC and relevant local
codes.
CAUTION
Do not exceed the specified voltage and current input.
FL Luminaires have no serviceable parts. Do not attempt to open the units.
Do not use a luminaire with a dmaged lens body or cable.
Do not hot swap. Ensure power supply is off before connecting or disconnecting fixtures.
Install according to local and national electric codes.
Make all connections within a suitable waterproof junction box (supplied by others)
Power and data connections should be made in separate junction boxes
End-of-line resistor (120 OHM) must be connected to data+ (white) and data - (blue) output of last
luminaire on data line, isolarte common output.
GVA Lighting, Inc. recommends the use of WAGO Service connectors or terminal blocks or solder
joints for proper stable installation. (supplied by others)
Ignoring a hazard voids any warranty.
FL