background image

THERMOSTAT BD06

SEMI-PROGRAMMABLE DIGITAL - WHITE

USER MANUAL

I - INTRODUCTION

II -  TECHNICAL PARAMETERS AND MAIN CHARACTERISTICS

Technical parameters

Voltage

AC 230V, 50-60Hz

Amperage

16 A

Working environment

0ºC ~70ºC 

Consumption

<0.3 W

Protection index

IP20

Programmable temperature

5ºC ~ 35ºC 

Temperature control precision

0.5 ºC

Main characteristics

Programs

3 daily, cyclic active scheduling

Probe reading options

3 (internal, external and both)

External dimensions

86mm x 86mm x 27mm

Material

PC + ABS

Screen background color

Blue

Memory in case of electrical failure

Time and schedules

Child lock

Yes

Installation

Wall-Inserted Type

III - CAUTIONS FOR INSTALLATION

IV - INSTALLATION

1. Separate the thermostat from the display using a screwdriver to press the 

groove at the back of the thermostat and pushing the display upwards (fig.1).
2. Follow the wiring diagram (fig. 2) to connect the power, the heating cable 

and the floor probe.
3. Use the two screws provided to fix the outer ring and the thermostat base 

to the electrician's deep box previously installed (fig. 3) and make sure that it 

is properly installed.
4. Attach the display to the four projections on the mounting plate and push it 

downwards (never press the LCD display directly). The installation is complete. 

Turn on the power to test the thermostat.

Fig. 1 - Thermostat opening

1 2 3 4

5

L1 N1

N

L

6

N

TC

Load

IP 20

AC230V 50/60Hz

current imax:16A

Fig. 2 - Wiring diagram

Fig. 3 - Thermostat Installation

Switch on / off thermostat.

Press for 3s to activate / deactivate child lock
Rotate clock wise Increases the Value, Rotate in the opposite direction

Decreases Value

Fast Press Confirms the option (Enter key)

Pressing for 3s, when released, enters settings mode

P

1

P

2

P

3

PROG

TIME

F C

F C

SET

ROOM

NTC

0

6

12

18

24

AUTO

Child lock

Programs 1 2 and 3

Energy Saver Mode

Confort Mode

Heating

Hours

24 hours of the day

Programming Symbol

Days of the week

Advanced Options symbol

Set temperature

Room temperature

Automatic mode

Manual mode 

Anti-freeze mode

Vacation Mode

V - THERMOSTAT INTERFACE

Funções dos botões

TIME

VI - THERMOSTAT PROGRAMMING

»

ON / OFF

Press the button      to turn on the thermostat (located on the right side of the 

thermostat).
Press the button        again to turn off the thermostat and cut the power to the 

heating cable or network.

»

SETTING THE TIME AND DAY OF THE WEEK

With the thermostat on, press the button       and release after 3 seconds to 

enter the settings mode.
Turn the knob       until the symbol               flashes and short press the button     

to enter the Hour and day of the week settings.
Rotate the knob to set the minutes and confirm with a short press on the 

same button, after the minutes the hours follow with the same procedure.
After setting the hours and pressing the button        , you will see the days of 

the week flash (                               ). 1 represents Monday, 6 represents Saturday 

and 7 represents Sunday. After setting the day of the week, press the button 

again to exit the menu and wait 5 seconds to exit the settings mode.

Dear User:
Congratulations on chhosing a           thermostat.  Please refer to this user 

manual before installing/using the thermostat.
This thermostat is used to control the temperature of heating cables or 

heating mats for electric underfloor heating in a given room, wether in a 

domestic, commercial or industrial environment.
While we try to provide the best device possible, we are always available for 

technical support. If you have any questions, please contact us.

ATTENTION!

When being installed, this thermostat may cause an

electric shock. Make sure the installation is done by

a qualified electrician.

1. Installation should only be done when the electric supply is off, otherwise it can 

damage the thermostat and cause an electric shock.
2. Choose the most suitable location for installing the thermostat (about 1,60m 

above the floor). It must not be installed at eye level.
3. Installation should not be made at altitudes higher then 2000m above sea level.

Heating Cable / Mat

16A

N (Neutral Wire)

L (Live wire)

AC220V, 50~60Hz

Floor Sensor