Connection tests will indicate the radio signal strength (RSSI value) between any two
devices. This value is always negative, and will generally range from -50 to -120, with -50 to
-70 being excellent, -70 to -90 being good, and any value above being a
poor connection. An RSSI value between -90 and -99 may work if necessary, but -100 and above
should be avoided if possible. RSSI values worse than -100 are unreliable and may not transmit data if
minor weather conditions - such as fog
–
occur.
5.1.8
Finalize the changes
When you are done, you need to upload the changes you made to the ZONESCAN net for them to
become effective. Go to
‘
Project Management
’
and tap
‘
upload
’
on your project.
Alternatively, go to the map on the top right corner where you will find the options menu. Click on
‘
Project
’
and select
‘
Upload
’
.