![Gutermann ZONESCAN User Manual Download Page 10](http://html.mh-extra.com/html/gutermann/zonescan/zonescan_user-manual_2279159010.webp)
ZONESCAN INSTALL User Manual page
–
6
4 NB-IoT Wizard
4.1
NB-IoT setup
This section explains the complete setup of NB-IoT loggers: from downloading an NB-IoT project from
ZSNet to deploying the logger to uploading the changed configuration to ZS-Net cloud.
Select an NB-
IoT project and click on ‘Download’ from the list of downloade
d projects to load an NBIoT
project. Then select the downloaded project to configure the gateway settings.
4.1.1
Configuring Gateway Settings
Configure the gateway settings to establish contact with the Gutermann gateway.
You need to fill in the following details on the Gateway Settings screen:
•
Gateway Address: Default address is set to ‘95.21
7.68.86
’
.
•
Port: Default port number is set to ‘45709’
. In the unlikely event that your network provider
has blocked port 45709, you can use port 8472 as an alternative.
•
APN: APN of your network provider must be set.
•
Username (Optional), Password (Optional), Network Operator (Optional): Leave empty unless
explicitly required by your network provider.
•
Bands: Select all the bands that your network provider supports.
•
Time offset: It is automatically set, and it is the same as the time offset set in ZSNet.
•
Network contact time: This is the delay before the NB-IoT Logger will try to register itself at
the gateway. The default time is set to 5 min.