GAP Pro Spray Gun
10
36943-1, Issue 1
Air Hose Configurations
TOOLS REQUIRED
•
3/16” Hex Key
•
(2) 6” Adjustable Wrench
The GAP PRO Gun design allows for two different Air Hose configurations. The
standard configuration has the air connection at the base of the handle. The optional
configuration has the air connection at the rear of the gun. To change to the optional
configuration proceed as follows:
Figure 6. Air Hose Configuration
WARNING
: B
EFORE ATTEMPTING THIS PROCEDURE
,
CLOSE BOTH
M
ANUAL
V
ALVES
,
ENGAGE
THE
S
AFETY
S
TOP
,
AND DISCONNECT THE AIR FROM THE GUN
.
1.
REMOVE THE AIR HOSE-
Using a 6” Adjustable Wrench remove the Air Hose
from the Long Pipe Nipple at the base of the gun handle.
2.
REMOVE THE LONG PIPE NIPPLE-
Using a 6” Adjustable Wrench, remove
the Long Pipe Nipple from the base of the gun handle.
3.
REMOVE THE PIPE PLUG-
Using the 3/16” Hex Key, remove the Pipe Plug
from the back of the gun.
4.
INSTALL THE PIPE PLUG-
Using the 3/16” Hex Key, install the Pipe Plug in the
base of the gun handle in the hole previously occupied by the Air Hose.
5.
INSTALL THE PIPE NIPPLE (Supplied with Gun)-
Using a 6” Adjustable
Wrench, install the Pipe Nipple in the back of the gun.
6.
INSTALL THE AIR HOSE-
Using a 6” Adjustable Wrench, connect the Air Hose
to the Pipe Nipple at the back of the gun.