Operating Manual
Initial Machine Set-up
2/12/04
13
The Accessory Package included with the unit contains the following parts required for set-
up:
•
Tape Roll
•
Isolator
•
(2) Swivel Unions
•
Isolation Hoses
Blue – Resin
Red – Isocyanate
•
1/4 x 30” (76 cm) Air Hose
•
Temperature Sensing Unit (TSU)
•
Parts Identification Manual
•
Binder
•
Warranty Card
•
Hose Jumper Plug
•
TSU Extension Adapter
∗
∗
Refer to Figure 2 for additional parts required for set-up.
IMPORTANT: Complete and return the Warranty Validation Card within 2 weeks
of receipt of equipment.
Main Power Installation
WARNING:
B
EFORE PROCEEDING
,
BE SURE THAT INCOMING POWER IS DISCONNECTED AND
LOCKED OUT AT THE SOURCE
.
IMPORTANT: The main power source must be capable of meeting the electrical
requirements specified on the nameplate of the proportioning unit and an accessible
quick disconnect provided.
1. Remove and retain four (4) screws from the console cover. Open the cover.
2. Connect the main power cord to the electrical console using wire size #10 or larger.
(Not supplied)
(See
Figure 3
.)
a) Feed the power cord through the strain relief in the back of the console and
connect the power leads to L1 and L2 (220V)
–or-
L1, L2 and L3 (380V).
b) Connect the ground wire to the ground lug.
c) For 380V models, connect the white Neutral lead to position N on the terminal
block.
(220V Single-Phase)
(380V-Three Phase)
Figure 3. Main Power Connections