Status displays
5
· G&D MultiPower-12
Status displays
The
Load
and
Power
LEDs on the front and the
back panel of the central power supply show the
device status and the load of active devices.
The LED next to each
Power Out
socket on the back
panel shows the status of the socket.
Section
LED
Status
Meaning
Load
The load of the active devices is displayed in an LED scale.
Four green and two yellow LEDs highlight the reaching of
the maximum load.
If the maximum load is exceeded, one or two red LEDs
light up.
Note:
If one or two red LEDs indicate that the temperature
within the device is too high, make sure to cool the device.
Power
Red.
On
The power pack is turned on and supplies the required
voltage.
Off
The power pack is turned off, or there is no connection to
the mains.
Main
On
The power pack is turned on and supplies the required
voltage.
Off
The power pack is turned off, or there is no connection to
the mains.
Section
LED
Status
Meaning
Power Out [x]
Status
On
Voltage available at this output.
Off
No voltage available at this output.
In case of an overload or a short circuit, the output is disa-
bled but becomes active after 10 seconds.
Load
Red.
Main
Power
Power Out 2
Power Out 3
Power Out 1
Power Status