Technical Data
G&D FIBREVision-USB 2.0 ·
24
Transmission Module Features
MULTIMODE TRANSMISSION MODULE
Data transmission
Mode:
Fibre optics (2 fibres)
Interface:
LC Duplex
Cable length (max.)
Multimode 50/125
μ
m,
class OM2:
550 meters (fibres with 500 MHz*km),
500 meters (fibres with 400 MHz*km)
Multimode 62
.
5/125
μ
m,
class OM1:
220 meters (fibres with 160 MHz*km),
275 meters (fibres with 200 MHz*km)
Performance data
Wavelength (
):
850 nm (770 nm to 860 nm)
Optical power output (P
AVG
)
in 50 oder 62
.
5
μ
m MMF:
-9
.
5 dBm
to
-3 dBm
Receiver sensitivity (P
MIN
):
-17 dBm
Sensitivity – Stressed (P
S
):
-13
.
5 dBm (50
µ
m MMF)
SINGLEMODE TRANSMISSION MODULE
Data transmission
Art:
Fibre optics (2 fibres)
Port type:
LC Duplex
Cable length (max.)
Singlemode 9/125
μ
m,
class OS1:
2 kilometers
Wavelength (
):
1310 nm (1270 nm
to
1360 nm)
Performance data
Optical power output (P
AVG
)
in 9
μ
m SMF:
-9
.
5 dBm to -3 dBm
Receiver sensitivity (P
MIN
):
-19 dBm
Sensitivity – Stressed (P
S
):
-14
.
4 dBm