Modular design of the matrix switch
G&D ControlCenter-Digital-288 ·
9
English
The 18 ports of each
IO card (3)
let you connect the user modules or the target mod-
ules of the KVM system.
Each
fan board (4)
is equipped with ten fans. The fans of the
Fan IN
board draw the
outside air into the device. The fans of the
Fan OUT
board blow the air out of the
device.
To protect the components in the housing from dust, a filter is placed in front of
the fans of the
Fan IN
board.
Up to three
power supply modules (5)
provide power to the matrix switch. If you use
at least two power supply modules, you can replace one of them during operation.
Installing or replacing components
Installing or replacing IO cards
IO cards can be installed (hot plug) or replaced (hot swap) during operation.
IMPORTANT:
Change the filters regularly. The time between changing the filter
depends on how much dust the devices are exposed to:
Strong exposure to dust:
1 month
Moderate exposure to dust:
3 months
Light exposure to dust:
6 months
Check the filter condition regularly. Tap the filter or use light blows of compres-
sed air to clean the filter. Change the filter at the latest after six months.
NOTE:
By distributing the load, power is supplied to all active power supply
modules.
The IO Card
CCD-IO16-Card-Fiber
uses components with laser technology which
comply with laser class 1.
They meet the requirements in accordance to
EN 60825-1:2014
as well as
U.S. CFR 1040.10
and
1040.11
.
Mind the following instructions when dealing with laser beams:
Avoid direct eye exposure to beam
Always connect optical connections or cover them with protection caps